// CODE SNIPPET
1705.2.3 Open-Web Steel Joists and Joist Girders
JUMP TO FULL CODE CHAPTER
Special inspections of open-web steel joists and joist girders in buildings, structures and portions thereof shall be in accordance with Table 1705.2.3.
TYPE | CONTINUOUS SPECIAL INSPECTION |
PERIODIC SPECIAL INSPECTION |
REFERENCED STANDARDa |
1.Installation of open-web steel joists and joist girders. | |||
a. End connections — welding or bolted. | — | X | SJI specifications listed in Section 2207.1. |
b. Bridging — horizontal or diagonal. | — | — | — |
1.Standard bridging. | — | X | SJI specifications listed in Section 2207.1. |
2.Bridging that differs from the SJI
specifications listed in Section 2207.1.
|
— | X | — |
For SI: 1 inch = 25.4 mm.
- Where applicable, see Section 1705.12, Special inspections for seismic resistance.
Related Code Sections
1705.2.3 Special Inspections and Tests, Open-Web Steel Joists and Joist Girders
Special inspections of open-web steel joists and joist girders in buildings, structures and portions thereof shall be in accordance with Table ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.2 Steel Construction > 1705.2.3 Open-Web Steel Joists and Joist Girders
1616.2.2 Structural Design, Structural Steel, Open Web Steel Joist or Joist Girder, or Composite Steel and Concrete Frame Structures
Frame structures constructed with a structural steel frame or a frame composed of open web steel joists, joist girders with or without other ...
Building Code 2018 of Illinois > 16 Structural Design > 1616 Structural Integrity > 1616.2 Frame Structures > 1616.2.2 Structural Steel, Open Web Steel Joist or Joist Girder, or Composite Steel and Concrete Frame Structures
2207.1 Steel, General
The design, manufacture and use of open-web steel joists and joist girders shall be in accordance with either SJI 200 or SJI 100, as applicable ...
Section 2203 Steel, Protection of Steel for Structural Purposes
Painting of structural steel elements shall be in accordance with AISC 360. Painting of open-web steel joists and joist girders shall ...
1704.5 Special Inspections and Tests, Submittals to the Building Official
tests for shotcrete in accordance with Section 1908.5. Certificates of compliance for open web steel joists and joist girders in accordance ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1704 Special Inspections and Tests, Contractor Responsibility and Structural Observation > 1704.5 Submittals to the Building Official