• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

M1503.2.1 Open-Top Broiler Exhaust

Residential Code 2018 of Kansas > 15 Exhaust Systems > M1503 Domestic Cooking Exhaust Equipment > M1503.2 Domestic Cooking Exhaust > M1503.2.1 Open-Top Broiler Exhaust
JUMP TO FULL CODE CHAPTER
Domestic open-top broiler units shall be provided with a metal exhaust hood having a thickness of not less than 0.0157 inch (0.3950 mm) (No. 28 gage). Such hoods shall be installed with a clearance of not less than 1/4 inch (6.4 mm) between the hood and the underside of combustible material and cabinets. A clearance of not less than 24 inches (610 mm) shall be maintained between the cooking surface and combustible material and cabinets. The hood width shall be not less than the width of the broiler unit and shall extend over the entire unit.
Exception: Broiler units that incorporate an integral exhaust system, and that are listed and labeled for use without an exhaust hood, shall not be required to have an exhaust hood.

Related Code Sections


M1503.2.1 Exhaust Systems, Open-Top Broiler Exhaust
Domestic open-top broiler units shall be provided with a metal exhaust hood having a thickness of not less than 0.0157 inch (0.3950 mm) (No. 28 gage ...
Residential Code 2018 of Kansas > 15 Exhaust Systems > M1503 Domestic Cooking Exhaust Equipment > M1503.2 Domestic Cooking Exhaust > M1503.2.1 Open-Top Broiler Exhaust
505.6 Exhaust Systems, Other Than Group R
In other than Group R occupancies, where domestic cooktops, ranges, and open-top broilers are used for domestic purposes, domestic cooking exhaust ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 505 Domestic Cooking Exhaust Equipment > 505.6 Other Than Group R
623.5 Specific Appliances, Open-Top Broiler Unit Hoods
A ventilating hood shall be provided above a domestic open-top broiler unit, unless otherwise listed for forced down draft ventilation ...
Fuel Gas Code 2018 of Kansas > 6 Specific Appliances > 623 (IFGC) Cooking Appliances > 623.5 Open-Top Broiler Unit Hoods
506.5.6 Exhaust Systems, Termination Location
The outlet of exhaust equipment serving Type I hoods shall be in accordance with Section 506.3.13. Exception: The minimum horizontal distance ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 506 Commercial Kitchen Hood Ventilation System Ducts and Exhaust Equipment > 506.5 Exhaust Equipment > 506.5.6 Termination Location
M1504.3 Exhaust Systems, Exhaust Openings
Air exhaust openings shall terminate as follows: Not less than 3 feet (914 mm) from property lines. Not less than 3 feet (914 mm) from gravity air ...
Residential Code 2018 of Kansas > 15 Exhaust Systems > M1504 Exhaust Ducts and Exhaust Openings > M1504.3 Exhaust Openings
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING