10.10.4 Open Fires
JUMP TO FULL CODE CHAPTER
Permitted open fires shall be located not less than 50 ft (15 m) from any structure.
Burning hours shall be prescribed by the AHJ.
Recreational fires shall not be located within 25 ft (7.6 m) of a structure or combustible material unless contained in an approved manner.
Conditions that could cause a fire to spread to within 25 ft (7.6 m) of a structure shall be eliminated prior to ignition.
Related Code Sections
10.10.4 General Safety Requirements, Open Fires
Permitted open fires shall be located not less than 50 ft (15 m) from any structure ...
Fire Code 2018 of Maine > 10 General Safety Requirements > 10.10 Open Flames, Candles, Open Fires, and Incinerators > 10.10.4 Open Fires
10.10.3 General Safety Requirements, Outdoor Fires
Outdoor fires shall not be built, ignited, or maintained in or upon hazardous fire areas, except by permit from the AHJ ...
Fire Code 2018 of Maine > 10 General Safety Requirements > 10.10 Open Flames, Candles, Open Fires, and Incinerators > 10.10.3 Outdoor Fires
10.10.5 General Safety Requirements, Fire Attendant
Open, recreational, and cooking fires shall be constantly attended by a competent person until such fire is extinguished ...
Fire Code 2018 of Maine > 10 General Safety Requirements > 10.10 Open Flames, Candles, Open Fires, and Incinerators > 10.10.5 Fire Attendant
10.10.10* General Safety Requirements, Discontinuance
The AHJ shall be authorized to require any fire or smoke to be immediately discontinued if the fire is determined to constitute a hazardous condition ...
Fire Code 2018 of Maine > 10 General Safety Requirements > 10.10 Open Flames, Candles, Open Fires, and Incinerators > 10.10.10* Discontinuance
10.10.9 General Safety Requirements, Open-Flame Devices
Welding torches, tar pots, decorative torches, and other devices, machines, or processes liable to start or cause fire shall not be operated or used ...
Fire Code 2018 of Maine > 10 General Safety Requirements > 10.10 Open Flames, Candles, Open Fires, and Incinerators > 10.10.9 Open-Flame Devices