• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

93-66 Open Area Requirements in the Large-Scale Plan Subdistrict A

NYC Zoning Resolution > IX Special Purpose Districts > 3 - Special Hudson Yards District (HY) > 93-60 Mandatory Improvements > 93-66 Open Area Requirements in the Large-Scale Plan Subdistrict A
JUMP TO FULL CODE CHAPTER
In Subareas A2 through A5 of the Large-Scale Plan Subdistrict A, the provisions of this Section shall apply to all open areas between the street wall of any development or enlargement and the street line.
(a)        Where such open areas are sidewalk widenings required pursuant to Section 93-61, or where a sidewalk widening is not required but an open area extends along the entire street line of the zoning lot, no obstructions shall be permitted within such open areas within five feet of the street line. Beyond five feet of the street line, up to a distance of 10 feet from the street line, obstructions shall be limited to seating, tables, and trees planted flush to grade. Any open area provided beyond 10 feet of the street line shall comply with the provisions of paragraphs (b) through (d) of this Section, as applicable.
(b)        All open areas less than 1,200 square feet in area, or open areas of any size but with a width or depth of less than 30 feet, shall be paved or contain landscaping. Paved areas shall be at the same elevation as the adjoining sidewalk or any adjoining public access area required pursuant to this Chapter.
(c)        All open areas at least 1,200 square feet in area, and with a width and depth of at least 30 feet, shall be paved and contain landscaping. Paved areas shall not be more than 2 feet, 6 inches above or below the level of the adjoining sidewalk or any adjoining public access area required pursuant to this Chapter.
(d)        Open areas described in paragraphs (b) and (c) of this Section may be occupied by features, equipment and appurtenances normally found in public parks and playgrounds, as listed in Section 37-726 (Permitted obstructions). In addition, gates or fences shall be permitted for open areas described in paragraph (c) of this Section, provided such gates are fully open during business hours, such gates or fences are not higher than five feet, and are a minimum of 65 percent open to permit visibility of the open area. No parking areas shall be permitted in any open area. Driveways in any open area shall lead directly to an enclosed parking or loading facility, except that portes-cocheres are allowed in any open area on zoning lots with at least 80,000 square feet of lot area. Building trash storage facilities and mechanical equipment shall be screened by a wall or planted area sufficient to visually conceal these facilities from the street or any public access area. All paved areas shall be accessible to the public during business hours and have lighting with a minimum level of two foot candles. Edges of planters in all landscaped areas shall not be higher than 2 feet, 6 inches above the level of any adjacent paved area.

Related Code Sections


23.7.1.5 Plans and Calculations, Slatted Floors, Large Floor Openings, Mezzanines, and Large Platforms
Buildings having slatted floors or large unprotected floor openings without approved stops shall be treated as one area with reference to pipe sizes ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 23 Plans and Calculations > 23.7 Pipe Schedules > 23.7.1* General > 23.7.1.5 Slatted Floors, Large Floor Openings, Mezzanines, and Large Platforms
21.5 Alternative Sprinkler System Designs for Chapters 12 Through 20, Minimum Obstruction Criteria
Sprinklers having standard coverage areas requiring up ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 21 Alternative Sprinkler System Designs for Chapters 12 Through 20 > 21.5 Minimum Obstruction Criteria
1028.1.3 Means of Egress, Approved Plans
of all exits. These plans shall not be smaller in size than required for 1 / 8 -inch scale plans ...
NYC Building Code 2014 > 10 Means of Egress > 1028 Assembly > 1028.1 General > 1028.1.3 Approved Plans
1029.1.5 Means of Egress, Approved Plans
These plans shall not be smaller in size than required for 1 / 8 -inch (3.2 mm) scale plans ...
NYC Building Code 2022 > 10 Means of Egress > 1029 Assembly > 1029.1 General > 1029.1.5 Approved Plans
1024.1.3 Means of Egress, Approved Plans
location of all exits.   These plans shall not be smaller in size than required for one-eighth inch scale plans ...
NYC Building Code 2008 > 10 Means of Egress > 1024 Assembly > 1024.1 General > 1024.1.3 Approved Plans
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING