1101.6.5 Open Area
JUMP TO FULL CODE CHAPTER
Nothing in Section 1101.6 shall prevent drains that serve either subsoil drains or areaways of a detached building from discharging to a properly graded open area, provided that:
- They do not serve continuously flowing springs or groundwater.
- The point of discharge is not less than 10 feet (3048 mm) from a property line.
- It is impracticable to discharge such drains to a storm drain, to an approved water course, to the front street curb or gutter, or to an alley.
Related Code Sections
1101.6.5 Storm Drainage, Open Area
graded open area, provided that: They do not serve continuously flowing springs or groundwater. The point of discharge is not less than 10 feet ...
Uniform Plumbing Code 2018 of Nevada > 11 Storm Drainage > 1101.0 General > 1101.6 Subsoil Drains > 1101.6.5 Open Area
R310.1.1 Building Planning, Minimum Opening Area
All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m 2 ). Exception: Grade floor openings ...
Residential Code 2012 of Nevada > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.1 Emergency Escape and Rescue Required > R310.1.1 Minimum Opening Area
R310.2.1 Building Planning, Minimum Opening Area
openings or below - grade openings shall have a net clear opening area of not less than 5 square feet (0.465 m 2 ) ...
Residential Code 2018 of Nevada > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.2 Emergency Escape and Rescue Openings > R310.2.1 Minimum Opening Area
Section G2453 Fuel Gas, (634) Chimney Damper Opening Area
opening equal to or greater than specified in Table G2453.1.
TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM ...
Section G2453 Fuel Gas, (634) Chimney Damper Opening Area
opening equal to or greater than specified in Table G2453.1. TABLE G2453.1 (634.1) FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASESFROM ...