Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

602.2.1 Onsite Electricity

Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 602 Modeled Performance Pathway Requirements > 602.2 Annual Direct and Indirect Co2e Emissions > 602.2.1 Onsite Electricity
JUMP TO FULL CODE CHAPTER
Emissions associated with use of electric power shall be based on electric power excluding any renewable or recovered waste energy covered under Section 602.2.1. Emissions shall be calculated by converting the electric power used by the building at the electric utility meter or measured point of delivery, to MWHs, and multiplying by the CO2e conversion factor in Table 602.2.1 based on the EPA eGRID Sub-region in which the building is located.
TABLE 602.2.1
ELECTRICITY EMISSION RATE BY EPA eGRID SUB-REGIONa
eGRID 2007 SUB-
REGION ACRONYM
eGRID 2007 SUB-REGION
NAME
2005 CO2e RATE
(lbs/MWh)
AKGDASCC Alaska Grid1270
AKMSASCC Miscellaneous515
ERCTERCOT All1417
FRCCFRCC All1416
HIMSHICC Miscellaneous1595
HIOAHICC Oahu18591
MOREMRO East1971
MROWMRO West1957
NYLINPCC Long Island1651
NEWENPCC New England999
NYCWNPCC NYC/Westchester874
NYUPNPCC Upstate NY774
RFCERFC East1224
RFCMRFC Michigan1680
RFCWRFC West1652
SRMWSERC Midwest1966
SRMVSERC Mississippi Valley1094
SRSOSERC South1601
SRTVSERC Tennessee Valley1623
SRVCSERC Virginia/Carolina1220
SPNOSPP North2106
SPSOSPP South1780
CAMXWECC California768
NWPPWECC Northwest958
RMPAWECC Rockies1999
AZNMWECC Southwest1391
a. Sources: EPA eGRID2007 Version 1.1, 2005 data; EPA eGrid regional gross grid loss factor.

Related Code Sections


602.2.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Onsite Electricity
Emissions associated with use of electric power shall be based on electric power excluding any renewable or recovered waste energy covered under ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 602 Modeled Performance Pathway Requirements > 602.2 Annual Direct and Indirect Co2e Emissions > 602.2.1 Onsite Electricity
608.12 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Main Electrical Panel Rating
The main electrical service entrance panel for the building shall be listed and labeled as a suitable connection to an onsite renewable energy source ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 608 Building Electrical Power and Lighting Systems > 608.12 Main Electrical Panel Rating
607.4 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Snowmelt Systems
25 percent of the design snow melting total annual consumption measured in Btu/ft 2 (J/m 2 ), energy per unit area. Electric systems shall ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 607 Building Service Water Heating Systems > 607.4 Snowmelt Systems
604.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Establishing an Open and Interoperable Automated Demand-Response (Auto-DR) Infrastructure
: Buildings located where the electric utility or regional Independent System Operator (ISO) or Regional Transmission Operator (RTO) does not offer ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 604 Automated Demand-Response (Auto-DR) Infrastructure > 604.1 Establishing an Open and Interoperable Automated Demand-Response (Auto-DR) Infrastructure
Section 610 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Building Renewable Energy Systems
of the building, or collective buildings on the site, with onsite renewable energy using a combination of renewable energy generation systems complying ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 610 Building Renewable Energy Systems
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING