// CODE SNIPPET
602.2.1 Onsite Electricity
JUMP TO FULL CODE CHAPTER
Emissions associated with use of electric power shall be based on electric power excluding any renewable or recovered waste energy covered under Section 602.2.1. Emissions shall be calculated by converting the electric power used by the building at the electric utility meter or measured point of delivery, to MWHs, and multiplying by the CO2e conversion factor in Table 602.2.1 based on the EPA eGRID Sub-region in which the building is located.
TABLE 602.2.1
ELECTRICITY EMISSION RATE BY EPA eGRID SUB-REGIONa
ELECTRICITY EMISSION RATE BY EPA eGRID SUB-REGIONa
eGRID 2007 SUB- REGION ACRONYM | eGRID 2007 SUB-REGION NAME | 2005 CO2e RATE (lbs/MWh) |
AKGD | ASCC Alaska Grid | 1270 |
AKMS | ASCC Miscellaneous | 515 |
ERCT | ERCOT All | 1417 |
FRCC | FRCC All | 1416 |
HIMS | HICC Miscellaneous | 1595 |
HIOA | HICC Oahu | 18591 |
MORE | MRO East | 1971 |
MROW | MRO West | 1957 |
NYLI | NPCC Long Island | 1651 |
NEWE | NPCC New England | 999 |
NYCW | NPCC NYC/Westchester | 874 |
NYUP | NPCC Upstate NY | 774 |
RFCE | RFC East | 1224 |
RFCM | RFC Michigan | 1680 |
RFCW | RFC West | 1652 |
SRMW | SERC Midwest | 1966 |
SRMV | SERC Mississippi Valley | 1094 |
SRSO | SERC South | 1601 |
SRTV | SERC Tennessee Valley | 1623 |
SRVC | SERC Virginia/Carolina | 1220 |
SPNO | SPP North | 2106 |
SPSO | SPP South | 1780 |
CAMX | WECC California | 768 |
NWPP | WECC Northwest | 958 |
RMPA | WECC Rockies | 1999 |
AZNM | WECC Southwest | 1391 |
a. Sources: EPA eGRID2007 Version 1.1, 2005 data; EPA eGrid regional gross grid loss factor.
Related Code Sections
602.2.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Onsite Electricity
Emissions associated with use of electric power shall be based on electric power excluding any renewable or recovered waste energy covered under ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 602 Modeled Performance Pathway Requirements > 602.2 Annual Direct and Indirect Co2e Emissions > 602.2.1 Onsite Electricity
608.12 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Main Electrical Panel Rating
The main electrical service entrance panel for the building shall be listed and labeled as a suitable connection to an onsite renewable energy source ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 608 Building Electrical Power and Lighting Systems > 608.12 Main Electrical Panel Rating
607.4 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Snowmelt Systems
25 percent of the design snow melting total annual consumption measured in Btu/ft 2 (J/m 2 ), energy per unit area. Electric systems shall ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 607 Building Service Water Heating Systems > 607.4 Snowmelt Systems
604.1 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Establishing an Open and Interoperable Automated Demand-Response (Auto-DR) Infrastructure
: Buildings located where the electric utility or regional Independent System Operator (ISO) or Regional Transmission Operator (RTO) does not offer ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 604 Automated Demand-Response (Auto-DR) Infrastructure > 604.1 Establishing an Open and Interoperable Automated Demand-Response (Auto-DR) Infrastructure
Section 610 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Building Renewable Energy Systems
of the building, or collective buildings on the site, with onsite renewable energy using a combination of renewable energy generation systems complying ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 610 Building Renewable Energy Systems