E.6 One-Pipe Sanitary Drainage Systems Employing Aerator and Deaerator Stack Fittings
JUMP TO FULL CODE CHAPTER
- One-pipe sanitary drainage systems employing aerator and deaerator stack fittings shall be permitted to be installed in accordance with (1) the fitting manufacturer's current piping design manual and technical bulletins, and (2) the applicable requirements of this Code.
- The requirements of this Code shall supersede the fitting manufacturer's piping design manual with regard to acceptable piping materials, drainage fixture unit (DFU) values, and minimum drainage pipe sizes.
- Complete detailed layout drawings shall be prepared prior to the installation of such a sanitary drainage system.
Piping materials for drainage stacks and branches shall be in accordance with Section 3.5 of this Code. Piping materials for vents shall be in accordance with Section 3.6 of this Code.
Drainage fixture unit values for bathroom groups and individual fixtures shall be in accordance with Table 11.4.1 of this Code.
Piping in such a sanitary drainage system shall be sized according to the fitting manufacturer's current piping design manual. EXCEPTION: Drainage pipe sizes shall not be less than those required by Section 11.5 of this Code.
Piping shall be arranged as illustrated in the fitting manufacturer's current design manual. Maximum pipe lengths and minimum pipe sizes shall be as indicated.
The requirements of Sections E.1, E.2, E.3, and E.4 apply to this special design plumbing system.
Related Code Sections
E.6 Special Design Plumbing Systems, One-Pipe Sanitary Drainage Systems Employing Aerator and Deaerator Stack Fittings
One-pipe sanitary drainage systems employing aerator and deaerator stack fittings shall be permitted to be installed in accordance with (1 ...
New Jersey Plumbing Code 2018 > E Special Design Plumbing Systems > E.6 One-Pipe Sanitary Drainage Systems Employing Aerator and Deaerator Stack Fittings
E.6.6 Special Design Plumbing Systems, Requirements for Special Design Plumbing Systems
The requirements of Sections E.1, E.2, E.3, and E.4 apply to this special design plumbing system ...
New Jersey Plumbing Code 2018 > E Special Design Plumbing Systems > E.6 One-Pipe Sanitary Drainage Systems Employing Aerator and Deaerator Stack Fittings > E.6.6 Requirements for Special Design Plumbing Systems