• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

AS107.1.1 One-Hour Rated Clay Plastered Wall

California Residential Code 2016 > S Strawbale Construction > AS107 Fire Resistance > AS107.1 Fire-Resistance Rating > AS107.1.1 One-Hour Rated Clay Plastered Wall
JUMP TO FULL CODE CHAPTER
One-hour fire-resistance-rated nonload-bearing clay plastered strawbale walls shall comply with all of the following:
  1. Bales shall be laid flat or on-edge in a running bond.
  2. Bales shall maintain thickness of not less than 18 inches (457 mm).
  3. Gaps shall be stuffed with straw-clay.
  4. Clay plaster on each side of the wall shall be not less than 1 inch (25 mm) thick and shall be composed of a mixture of 3 parts clay, 2 parts chopped straw and 6 parts sand, or an alternative approved clay plaster.
  5. Plaster application shall be in accordance with Section AS104.4.3.3 for the number and thickness of coats.

Related Code Sections


AS107.1.1 Strawbale Construction, One-Hour Rated Clay Plastered Wall
One-hour fire-resistance-rated nonload-bearing clay plastered strawbale walls shall comply with all of the following: Bales shall be laid flat ...
California Residential Code 2016 > S Strawbale Construction > AS107 Fire Resistance > AS107.1 Fire-Resistance Rating > AS107.1.1 One-Hour Rated Clay Plastered Wall
AS107.1.1 Strawbale Construction, One-Hour-Rated Clay-Plastered Wall
One-hour fire-resistance-rated nonload-bearing clay plastered strawbale walls shall comply with all of the following: Bales shall be laid flat ...
California Residential Code 2019 > S Strawbale Construction > AS107 Fire Resistance > AS107.1 Fire-Resistance Rating > AS107.1.1 One-Hour-Rated Clay-Plastered Wall
722.4 Fire and Smoke Protection Features, Clay Brick and Tile Masonry
) REINFORCED CLAY MASONRY COLUMNS COLUMN SIZE FIRE-RESISTANCE RATING (hours) 1 2 3 4 Minimum column dimension (inches) 8 10 12 14 ...
California Building Code 2016 (Vol 1 & 2) > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.4 Clay Brick and Tile Masonry
722.4 Fire and Smoke Protection Features, Clay Brick and Tile Masonry
= The fire-resistance rating of the individual wall (hours). pl = Coefficient for thickness of plaster. Values for R n 0.59 for use ...
California Building Code 2019 (Vol 1 & 2) > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.4 Clay Brick and Tile Masonry
722.4.1 Fire and Smoke Protection Features, Masonry Walls
-RESISTANCE PERIODS OF CLAY MASONRY WALLS MATERIAL TYPE MINIMUM REQUIRED EQUIVALENT THICKNESS FOR FIRE RESISTANCE a, b, c (inches) 1 hour ...
California Building Code 2019 (Vol 1 & 2) > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.4 Clay Brick and Tile Masonry > 722.4.1 Masonry Walls
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING