• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

8-402.2 One-Hour Construction

California Historical Building Code 2019 > 8-4 Fire Protection > 8-402 Fire-Resistive Construction > 8-402.2 One-Hour Construction
JUMP TO FULL CODE CHAPTER
Upgrading an existing qualified historical building or property to one-hour fire-resistive construction and one-hour fire-resistive corridors shall not be required regardless of construction or occupancy when one of the following is provided:
  1. An automatic sprinkler system throughout. See Section 8-410 for automatic sprinkler systems.
  2. An approved life-safety evaluation.
  3. Other alternative measures as approved by the enforcing agency.

Related Code Sections


8-402.2 Fire Protection, One-Hour Construction
Upgrading an existing qualified historical building or property to one-hour fire-resistive construction and one-hour fire-resistive corridors shall ...
California Historical Building Code 2019 > 8-4 Fire Protection > 8-402 Fire-Resistive Construction > 8-402.2 One-Hour Construction
8-402.2 Fire Protection, One-Hour Construction
Upgrading an existing qualified historical building or property to one-hour fire-resistive construction and one-hour fire-resistive corridors shall ...
California Historical Building Code 2022 > 8-4 Fire Protection > 8-402 Fire-Resistive Construction > 8-402.2 One-Hour Construction
8-402.2 Fire Protection, One-Hour Construction
Upgrading an existing qualified historical building or property to one-hour fire-resistive construction and one-hour fire-resistive corridors shall ...
California Historical Building Code 2016 > 8-4 Fire Protection > 8-402 Fire-Resistive Construction > 8-402.2 One-Hour Construction
407.12 Special Detailed Requirements Based on Occupancy and Use, Technology Equipment Center
barrier constructed in accordance with Section 707 and a 1-hour horizontal assembly constructed in accordance with Section 711 or both ...
California Building Code 2019 (Vol 1 & 2) > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.12 Technology Equipment Center
407.12 Special Detailed Requirements Based on Occupancy and Use, Technology Equipment Center
barrier constructed in accordance with Section 707 and a 1-hour horizontal assembly constructed in accordance with Section 711 or both ...
California Building Code 2022 (Vol 1 & 2) > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 and Group I-2.1 > 407.12 Technology Equipment Center
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING