• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1114.5 On-Site Stormwater Disposal System Installation

NYC Plumbing Code 2022 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation
JUMP TO FULL CODE CHAPTER
On-site stormwater disposal systems shall be installed in accordance the manufacturer's recommendations and shall conform to Sections 1114.5.1 through 1114.5.3.

1114.5.1 Support of Excavation

When an on-site stormwater disposal system installation requires an excavation deeper than 5 feet (1524 mm), the sides of the excavation shall be protected and maintained in accordance with Section 3304.4 of the New York City Building Code.

1114.5.2 Sand Column Installation

Where the installation of an on-site stormwater disposal system requires the installation of a sand column, measures shall be taken to ensure the sand column is installed without contamination by impervious materials.

1114.5.3 Verification

The department reserves the right to require a 24-hour test to verify the absorption of water in the installed on-site stormwater disposal system prior to final approval.

Related Code Sections


1114.5 Storm Drainage, On-Site Stormwater Disposal System Installation
On-site stormwater disposal systems shall be installed in accordance the manufacturer's recommendations and shall conform to Sections 1114.5.1 ...
NYC Plumbing Code 2014 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation
1114.5 Storm Drainage, On-Site Stormwater Disposal System Installation
On-site stormwater disposal systems shall be installed in accordance the manufacturer's recommendations and shall conform to Sections 1114.5.1 ...
NYC Plumbing Code 2022 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation
1114.5.1 Storm Drainage, Support of Excavation
When an on-site stormwater disposal system installation requires an excavation deeper than 5 feet (1524 mm), the sides of the excavation shall ...
NYC Plumbing Code 2022 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation > 1114.5.1 Support of Excavation
Section 1114 Storm Drainage, Private On-Site Stormwater Disposal Systems
On-site stormwater disposal systems shall be located at least 5 feet (1524 mm) from all lot lines except where the lot line ...
NYC Plumbing Code 2022 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems
Section 1114 Storm Drainage, Private On-Site Stormwater Disposal Systems
On-site stormwater disposal systems shall be installed in accordance ...
NYC Plumbing Code 2014 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING