• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R606.13.9.1 Offset Reinforcement

2014 FBC - Residential, 5th edition > 6 Wall Construction > R606 General Masonry Construction > R606.13 Reinforcement > R606.13.9 Continuity Multistory Construction > R606.13.9.1 Offset Reinforcement
JUMP TO FULL CODE CHAPTER
Vertical reinforcement shall be permitted to be offset between floor levels. Reinforcement for the lower story shall be anchored into the upper floor level bond beam and reinforcement for the upper story shall be anchored into the bond beams above and below in accordance with Section R606.13.8 and Figures R606.13.9A and R606.13.9B.

Related Code Sections


R606.13.9.1 Wall Construction, Offset Reinforcement
Vertical reinforcement shall be permitted to be offset between floor levels. Reinforcement for the lower story shall be anchored into the upper floor ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R606 General Masonry Construction > R606.13 Reinforcement > R606.13.9 Continuity Multistory Construction > R606.13.9.1 Offset Reinforcement
10.7.4.2 Columns,
If the column face is offset 3 in. or more, longitudinal bars shall not be offset bent and separate dowels, lap spliced with the longitudinal bars ...
Building Code Requirements for Structural Concrete of Florida > 10 Columns > 10.7 Reinforcement Detailing > 10.7.4 Offset Bent Longitudinal Reinforcement > 10.7.4.2
R609.5.2 Wall Construction, Multistory Shearwalls
Shearwall segments in an upper story shall be located directly over and within the length of shearwall segments in the story below. Reinforcement ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.5 Exterior Shearwalls > R609.5.2 Multistory Shearwalls
10.7.6.4.2 Columns,
If transverse reinforcement is provided to resist forces that result from offset bends, ties, hoops, or spirals shall be placed not more than 6 ...
Building Code Requirements for Structural Concrete of Florida > 10 Columns > 10.7 Reinforcement Detailing > 10.7.6 Transverse Reinforcement > 10.7.6.4 Lateral Support of Offset Bent Longitudinal Bars > 10.7.6.4.2
R606.3.7 Wall Construction, Masonry Bonding Pattern
In each wythe of masonry laid in running bond, head joints in successive courses shall be offset by not less ...
2017 FBC - Residential, 6th edition > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.7 Masonry Bonding Pattern
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING