• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1030.4.1 Occupied Side

NYC Building Code 2014 > 10 Means of Egress > 1030 Signage > 1030.4 Door Signs > 1030.4.1 Occupied Side
JUMP TO FULL CODE CHAPTER
Where reentry is not provided from a stair to every floor, a sign that reads, "NO REENTRY FROM THIS STAIR" shall be posted on the occupied side of the stair door at every floor.

Related Code Sections


1026.4.1 Means of Egress, Occupied Side
Where re-entry is not provided from a stair to every floor, a sign that reads, "NO RE-ENTRY FROM THIS STAIR" shall be posted on the occupied side ...
NYC Building Code 2008 > 10 Means of Egress > 1026 Signage > 1026.4 Door Signs > 1026.4.1 Occupied Side
1030.4.1 Means of Egress, Occupied Side
Where reentry is not provided from a stair to every floor, a sign that reads, "NO REENTRY FROM THIS STAIR" shall be posted on the occupied side ...
NYC Building Code 2014 > 10 Means of Egress > 1030 Signage > 1030.4 Door Signs > 1030.4.1 Occupied Side
§27-521.3 Special Uses and Occupancies, Construction
on the occupied side adjacent to glass panels authorized by subdivision (d) of this section is no more than four feet or the minimum atrium area is twelve ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 21 Atriums > §27-521.3 Construction
Article 7 Means of Egress [PDF] (page 19)
the occupied side without the use of a key. The following sign shall be posted on each such door on the side facing the occupied area, in letters at least two ...
NYC 1938 Code [PDF] > 7 Means of Egress
Section 1026 Means of Egress, Signage
be posted on the occupied side of the stair door at every floor ...
NYC Building Code 2008 > 10 Means of Egress > 1026 Signage
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE