• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

*§28-304.10 Occupant Notification for Elevator Work

NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 304 Elevators and Conveying Systems > *§28-304.10 Occupant Notification for Elevator Work
JUMP TO FULL CODE CHAPTER
In occupancy groups R-1 and R-2, when an elevator is to be out of service, a notice identifying the type of work to be performed and the expected start and end dates for such outage shall be provided in English, Spanish, and such other languages as the department may provide by rule, in accordance with sections 28-304.10.1 and 28-304.10.2.

*Section 28-304.10 was amended by: Local Law 47 of 2015. This law has an effective date of September 30, 2015.

*§28-304.10.1 Occupant Notification for Alteration Work

When an elevator is to be out of service for alteration work, notice shall be given to the residential occupants no fewer than 10 business days before the start of the work, except in the case of emergency repairs. This notification requirement does not apply to minor alterations and ordinary repairs.

*Section 28-304.10 was added by: Local Law 47 of 2015. This law has an effective date of September 30, 2015.

*§28-304.10.2 Occupant Notification for Other Elevator Service Outages

When all elevators servicing a building or any section of a building are expected to be out of service for two or more hours, notice shall be posted at least twenty-four hours before the start of the work. When all elevators servicing a building or any section of a building are expected to be out of service for less than two hours, or are out of service as the result of emergency work, notice is not required to be posted, except that where such outage lasts for two or more hours, notice shall be posted as soon as practicable after the commencement of such service outage.

*Section 28-304.10 was added by: Local Law 47 of 2015. This law has an effective date of September 30, 2015.

Related Code Sections


*§28-304.10 Maintenance of Buildings, Occupant Notification for Elevator Work
In occupancy groups R-1 and R-2, when an elevator is to be out of service, a notice identifying the type of work to be performed and the expected ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 304 Elevators and Conveying Systems > *§28-304.10 Occupant Notification for Elevator Work
*§28-304.10 Maintenance of Buildings, Occupant Notification for Elevator Work
In occupancy groups R-1 and R-2, when an elevator is to be out of service, a notice identifying the type of work to be performed and the expected ...
NYC General Admin. Provisions 2022 > 3 Maintenance of Buildings > 304 Elevators and Conveying Systems > *§28-304.10 Occupant Notification for Elevator Work
3008.10.1 Elevators and Conveying Systems, Notification Appliances
No fewer than one audible and one visible notification appliance shall be installed within each occupant evacuation elevator lobby ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.10 Emergency Voice/Alarm Communication System > 3008.10.1 Notification Appliances
3008.10.1 Elevators and Conveying Systems, Notification Appliances
Not fewer than one audible and one visible notification appliance shall be installed within each occupant evacuation elevator lobby ...
NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.10 Emergency Voice/Alarm Communication System > 3008.10.1 Notification Appliances
3304.3 Safeguards During Construction or Demolition, Notification
Prior to the commencement of soil or foundation work, notification shall be provided as follows ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.3 Notification
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING