• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-2087 Occupancy of Cellars and Basements in One- And Two-Family Dwellings

§27 ‒ Housing Maintenance Code > 3 Physical and Occupancy Standards for Dwelling Units > 5 Occupancy of Cellars and Basements > §27-2087 Occupancy of Cellars and Basements in One- And Two-Family Dwellings
JUMP TO FULL CODE CHAPTER
buildings bulletin
Linked Resources Available

This section has been clarified by a buildings bulletin issued by the Department of Buildings.

Learn more in the Linked Resources panel on the right.
   a.   Cellar occupancy: No room in the cellar of a one- or two-family dwelling shall be rented and no member of the family or families occupying the dwelling shall use such room for sleeping, eating or cooking purposes, except that a secondary kitchen for accessory cooking may be located in the cellar.
   b.   Use of basement by occupants of the dwelling:  A room in the basement of a one- or two-family dwelling may be occupied for living purposes by members of the family or families in conjunction with their occupancy of the dwelling if the following conditions are met:
      (1)   Such room complies with all of the requirements of this code for rooms which are not located in the cellar or basement; except that the minimum ceiling height required in one family dwellings shall be seven feet.
      (2)   Whenever the department determines that the subsoil conditions on the lot so require, the basement or other lowest floor and all exterior walls as high as the ground level shall be dampproofed and waterproofed.
   c.   Rental of basement:  An apartment, in the basement of a one-family dwelling may be occupied, unless otherwise prohibited under the zoning resolution of the city of New York, if it meets the requirements of subdivision b and all of the following conditions:
      (1)   Such basement occupancy is limited to one family which, for the purposes of this section, shall not include boarders.
      (2)   Every room shall have a window complying with the requirements of section 27-2062 of article one of this subchapter.
      (3)   The bottom of any yard or other required open space shall be no higher than six inches below the window sill of any required window in any room.
   d.   Conversion to multiple dwelling. No private dwelling of more than three stories in height which was erected after April eighteenth, nineteen hundred twenty-nine shall be converted to a multiple dwelling unless it complies with all the provisions of the multiple dwelling law applicable to dwellings erected after April eighteenth, nineteen hundred twenty-nine.

Related Code Sections


1203.4.1.4.3 Interior Environment, Basements and Cellars
Where openings provide natural ventilation to kitchenettes less than 80 square feet (7.4  m 2 ) located in basements or cellars ...
NYC Building Code 2008 > 12 Interior Environment > 1203 Ventilation > 1203.4 Natural Ventilation > 1203.4.1 Ventilation Area Required > 1203.4.1.4 Kitchenettes in R and I-1 Occupancies > 1203.4.1.4.3 Basements and Cellars
1203.4.1.4.3 Interior Environment, Basements and Cellars
Where openings provide natural ventilation to kitchenettes less than 80 square feet (7.4 m 2 ) located in basements or cellars, such opening shall ...
NYC Building Code 2014 > 12 Interior Environment > 1203 Ventilation > 1203.4 Natural Ventilation > 1203.4.1 Ventilation Area Required > 1203.4.1.4 Kitchenettes in R and I-1 Occupancies > 1203.4.1.4.3 Basements and Cellars
1203.5.1.4.3 Interior Environment, Basements and Cellars
Where openings provide natural ventilation to kitchenettes less than 80 square feet (7.4 m 2 ) located in basements or cellars, such opening shall ...
NYC Building Code 2022 > 12 Interior Environment > 1203 Ventilation > 1203.5 Natural Ventilation > 1203.5.1 Ventilation Area Required > 1203.5.1.4 Kitchenettes in Group R and I-1 Occupancies > 1203.5.1.4.3 Basements and Cellars
1205.2.3 Interior Environment, Basements and Cellars
Where rooms within a dwelling unit in a multiple dwelling are located in a cellar or a basement, such rooms shall have at least 1 / 2 ...
NYC Building Code 2008 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.3 Basements and Cellars
1205.2.3 Interior Environment, Basements and Cellars
Where rooms within a dwelling unit in a multiple dwelling are located in a cellar or a basement, such rooms shall have at least one-half ...
NYC Building Code 2014 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.3 Basements and Cellars
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING