• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(v) 3322.3.1.5 Occupancy Load

Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3322 Fireworks Showrooms > 3322.3 Retail Sales Showroom > 3322.3.1 Retail Sales Showroom Safety Requirements > 3322.3.1.5 Occupancy Load
JUMP TO FULL CODE CHAPTER
The maximum occupant load for any retail sales showroom shall not exceed one occupant per sixty square feet of gross floor area. The maximum occupant load may be increased to one occupant per thirty square feet of gross floor area if both of the following conditions are satisfied:
(a) A minimum of one means of egress approved by the building official and the state fire marshal is provided for each twenty-five occupants or fraction thereof.
(b) A minimum of three means of egress approved by the building official and the state fire marshal are located to provide direct access in separate directions from any point in the area served so as to minimize the possibility that adequate exit capacity would be blocked by any one fire or other emergency condition.

Related Code Sections


Section 1004 Means of Egress, Occupant Load
in accordance with this section. Where occupants from accessory areas egress through a primary space, the calculated occupant load for the primary space ...
Ohio Building Code 2011 > 10 Means of Egress > 1004 Occupant Load
Section 1004 Means of Egress, Occupant Load
travel includes intervening rooms, areas or spaces, cumulative occupant loads shall be determined in accordance with this section ...
Ohio Building Code 2017 > 10 Means of Egress > 1004 Occupant Load
Section 1004 Ohio Administrative Code 1301:7-7-10 Means of Egress, Occupant Load
in accordance with this paragraph . Where occupants from accessory areas egress through a primary space, the calculated occupant load for the primary space ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-10 Means of Egress > 1004 Occupant Load
Section 1004 Ohio Administrative Code 1301:7-7-10 Means of Egress, Occupant Load
travel includes intervening rooms, areas or spaces, cumulative occupant loads shall be determined in accordance with this paragraph ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-10 Means of Egress > 1004 Occupant Load
3322.1.9 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Occupant Load
A sufficiently sized and legible copy of the approved maximum occupant load shall be prominently posted within every retail sales or representative ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3322 Fireworks Showrooms > 3322.1 General Requirements > 3322.1.9 Occupant Load
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING