504.1.2 Occupancies With Separate Entrances
JUMP TO FULL CODE CHAPTER
When a building contains more than one occupancy and separate entrances are provided for individual occupancies, there shall be a main front entrance for each such occupancy, and a separate frontage space shall be provided for each main front entrance, except that a second frontage space is not required for a two-family Group R-3 occupancy if unobstructed access, 5 feet (1524 mm) in width, is provided to the rear yard and to the main front entrance of any dwelling unit from either side of the building that is not directly accessible from the public street, fire apparatus access road, or driveway. An open accessory parking area not less than 5 feet (1524 mm) in width shall be sufficient to constitute unobstructed access to the rear yard, regardless of the presence of parked vehicles in such parking area.
Related Code Sections
1105.1.8 Accessibility, Automatic Doors
1105.1.8 PUBLIC ENTRANCE WITH POWER-OPERATED DOORS
Occupancy
Occupant Load ≥
A-1, A-2, A-3, A-4, B, R-1
200
E, M
300
...
NYC Building Code 2022 > 11 Accessibility > 1105 Accessible Entrances > 1105.1 Public Entrances > 1105.1.8 Automatic Doors
1006.6 Dwelling Units and Sleeping Units, Site, Building, or Floor Entrance
Where a system permitting voice communication between a visitor and the occupant of the unit is provided at a location other than the unit entry door ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1006 Units With Accessible Communication Features > 1006.6 Site, Building, or Floor Entrance
1107.7.1.1 Accessibility, One Story With Type B Units Required
For occupancies in other than Group R-2, at least one story containing dwelling units or sleeping units intended to be occupied as a residence shall ...
NYC Building Code 2008 > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.7 General Exceptions > 1107.7.1 Buildings Without Elevator Service > 1107.7.1.1 One Story With Type B Units Required
8.7.4.3.3 General Requirements, Hoistway Entrances
Where new entrances are installed, the new entrances shall conform to 4.3.6, 4.3.7, and 4.3.8 ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.7 Alterations > 8.7.4 Alterations to Elevators With Other Types of Driving Machines > 8.7.4.3 Hand Elevators > 8.7.4.3.3 Hoistway Entrances
412.4.4 Special Detailed Requirements Based on Use and Occupancy, Heating Equipment
areas.
Entrance to the separated room shall be permitted by a single interior door, provided the sources of ignition in the appliances are not less ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 412 Aircraft-Related Occupancies > 412.4 Aircraft Hangars > 412.4.4 Heating Equipment