• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2304.2.4 Obstructions to View

Fire Code 2018 of Colorado > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2304 Dispensing Operations > 2304.2 Attended Self-Service Motor Fuel-Dispensing Facilities > 2304.2.4 Obstructions to View
JUMP TO FULL CODE CHAPTER
Dispensing devices shall be in clear view of the attendant at all times. Obstructions shall not be placed between the dispensing area and the attendant.

Related Code Sections


2304.2.4 Motor Fuel-Dispensing Facilities and Repair Garages, Obstructions to View
The attendant shall have a direct line of sight to observe fuel-dispensing operations at all times. Obstructions shall not be placed between ...
Fire Code 2021 of Colorado > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2304 Dispensing Operations > 2304.2 Attended Self-Service Motor Fuel-Dispensing Facilities > 2304.2.4 Obstructions to View
2304.2.4 Motor Fuel-Dispensing Facilities and Repair Garages, Obstructions to View
Dispensing devices shall be in clear view of the attendant at all times. Obstructions shall not be placed between the dispensing area ...
Fire Code 2018 of Colorado > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2304 Dispensing Operations > 2304.2 Attended Self-Service Motor Fuel-Dispensing Facilities > 2304.2.4 Obstructions to View
17.16.1.4 Initiating Devices,
An initiating device for supervising the position of a control valve shall not interfere with the operation of the valve, obstruct the view of its ...
National Fire Alarm and Signaling Code 2013 of Colorado > 17 Initiating Devices > 17.16 Supervisory Signal-Initiating Devices > 17.16.1 Control Valve Supervisory Signal-Initiating Device > 17.16.1.4
6.1.6.9.2 Escalators and Moving Walks, Signs or Graphics Relating to Safety
' view of the signs required in 6.1.6.9.1, physically obstruct passenger flow at the landings as specified in the safety zone (see 6.1.3.6.4 ...
Safety Code for Elevators and Escalators 2019 of Colorado > 6 Escalators and Moving Walks > 6.1 Escalators > 6.1.6 Operating and Safety Devices > 6.1.6.9 Signs > 6.1.6.9.2 Signs or Graphics Relating to Safety
6.2.6.9.2 Escalators and Moving Walks, Signs or Graphics Relating to Safety
' view of the signs required in 6.2.6.9.1, physically obstruct passenger flow at the landings as specified in the safety zone (see 6.2.3.8.4 ...
Safety Code for Elevators and Escalators 2019 of Colorado > 6 Escalators and Moving Walks > 6.2 Moving Walks > 6.2.6 Operating and Safety Devices > 6.2.6.9 Signs > 6.2.6.9.2 Signs or Graphics Relating to Safety
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING