// CODE SNIPPET
1910.1027(n)(2) Objective Data for Exemption From Requirement for Initial Monitoring
JUMP TO FULL CODE CHAPTER
For purposes of this section, objective data are information demonstrating that a particular product or material containing cadmium or a specific process, operation, or activity involving cadmium cannot release dust or fumes in concentrations at or above the action level even under the worst-case release conditions. Objective data can be obtained from an industry-wide study or from laboratory product test results from manufacturers of cadmium-containing products or materials. The data the employer uses from an industry-wide survey must be obtained under workplace conditions closely resembling the processes, types of material, control methods, work practices and environmental conditions in the employer's current operations.
The employer shall establish and maintain a record of the objective data for at least 30 years.
Related Code Sections
1910.1027(n)(2) Toxic and Hazardous Substances, Objective Data for Exemption From Requirement for Initial Monitoring
release conditions. Objective data can be obtained from an industry-wide study or from laboratory product test results from manufacturers of cadmium ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1027 Cadmium > 1910.1027(n) Recordkeeping > 1910.1027(n)(2) Objective Data for Exemption From Requirement for Initial Monitoring
1910.1047(k)(1)(i) Toxic and Hazardous Substances,
(a)(2) of this section, or where objective data have been relied on in lieu of initial monitoring under paragraph (d)(2)(ii) of this section ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1047 Ethylene Oxide > 1910.1047(k) Recordkeeping > 1910.1047(k)(1) Objective Data for Exempted Operations > 1910.1047(k)(1)(i)
1910.1051(m)(1)(i) Toxic and Hazardous Substances,
paragraph (a)(2) of this section, or where objective data have been relied on in lieu of initial monitoring under paragraph (d)(2)(ii) of this section ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1051 1,3-Butadiene > 1910.1051(m) Recordkeeping > 1910.1051(m)(1) Objective Data for Exemption From Initial Monitoring > 1910.1051(m)(1)(i)
1910.1050(n)(1) Toxic and Hazardous Substances, Monitoring Data for Exempted Employers
Where as a result of the initial monitoring the processing, use, or handling of products made from or containing MDA are exempted from other ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1050 Methylenedianiline > 1910.1050(n) Recordkeeping > 1910.1050(n)(1) Monitoring Data for Exempted Employers
1910.1052(m)(1) Toxic and Hazardous Substances, Objective Data
Where an employer seeks to demonstrate that initial monitoring is unnecessary through reasonable reliance on objective data showing that any ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1052 Methylene Chloride > 1910.1052(m) Recordkeeping > 1910.1052(m)(1) Objective Data