• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

407.2.6 Nursing Home Cooking Facilities

Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.2 Corridors Continuity and Separation > 407.2.6 Nursing Home Cooking Facilities
JUMP TO FULL CODE CHAPTER
In Group I-2, Condition 1 occupancies, rooms or spaces that contain a cooking facility with domestic cooking appliances shall be permitted to be open to the corridor where all of the following criteria are met:
  1. The number of care recipients housed in the smoke compartment shall not be greater than 30.
  2. The number of care recipients served by the cooking facility shall not be greater than 30.
  3. Not more than one cooking facility area shall be permitted in a smoke compartment.
  4. The types of domestic cooking appliances permitted shall be limited to ovens, cooktops, ranges, warmers and microwaves.
  5. The corridor shall be a clearly identified space delineated by construction or floor pattern, material or color.
  6. The space containing the domestic cooking facility shall be arranged so as not to obstruct access to the required exit.
  7. Domestic cooking hoods installed and constructed in accordance with Section 505 of the International Mechanical Code shall be provided over cooktops and ranges.
  8. Cooktops and ranges shall be protected in accordance with Section 904.13.
  9. A shut-off for the fuel and electrical power supply to the cooking equipment shall be provided in a location that is accessible only to staff.
  10. A timer shall be provided that automatically deactivates the cooking appliances within a period of not more than 120 minutes.
  11. A portable fire extinguisher shall be provided. Installation shall be in accordance with Section 906, and the extinguisher shall be located within a 30-foot (9144 mm) distance of travel from each domestic cooking appliance.

Related Code Sections


407.2.6 Special Detailed Requirements Based on Occupancy and Use, Nursing Home Cooking Facilities
In Group I-2, Condition 1 occupancies, rooms or spaces that contain a cooking facility with domestic cooking appliances shall be permitted to be open ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.2 Corridors Continuity and Separation > 407.2.6 Nursing Home Cooking Facilities
407.2.6 Special Detailed Requirements Based on Occupancy and Use, Nursing Home Cooking Facilities
In Group I-2, Condition 1 occupancies, rooms or spaces that contain a cooking facility with domestic cooking appliances shall be permitted to be open ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.2 Corridors Continuity and Separation > 407.2.6 Nursing Home Cooking Facilities
3.3.62 Definitions, Dwelling Unit (For Sprinkler System Installations)
in nursing homes, and similar living units ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 3 Definitions > 3.3 General Definitions > 3.3.62 Dwelling Unit (For Sprinkler System Installations)
517.40 Special Occupancies, Type 2 Essential Electrical Systems for Nursing Homes and Limited Care Facilities
Informational Note: Nursing homes and other limited care facilities can be classified as critical care (Category 1) or general care (Category 2 ...
National Electrical Code 2017 of Illinois > 5 Special Occupancies > 517 Health Care Facilities > 517.40 Type 2 Essential Electrical Systems for Nursing Homes and Limited Care Facilities
308.3.1.1 Occupancy Classification and Use, Condition 1
or in-patient stabilization units for psychiatric or detoxification, including but not limited to nursing homes and foster care facilities ...
Building Code 2021 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.3 Institutional Group I-2 > 308.3.1 Occupancy Conditions > 308.3.1.1 Condition 1
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING