407.2.6 Nursing Home Cooking Facilities
JUMP TO FULL CODE CHAPTER
In Group I-2, Condition 1 occupancies, rooms or spaces that contain a cooking facility with domestic cooking appliances shall be permitted to be open to the corridor where all of the following criteria are met:
- The number of care recipients housed in the smoke compartment shall not be greater than 30.
- The number of care recipients served by the cooking facility shall not be greater than 30.
- Not more than one cooking facility area shall be permitted in a smoke compartment.
- The types of domestic cooking appliances permitted shall be limited to ovens, cooktops, ranges, warmers and microwaves.
- The corridor shall be a clearly identified space delineated by construction or floor pattern, material or color.
- The space containing the domestic cooking facility shall be arranged so as not to obstruct access to the required exit.
- Domestic cooking hoods installed and constructed in accordance with Section 505 of the International Mechanical Code shall be provided over cooktops and ranges.
- Cooktops and ranges shall be protected in accordance with Section 904.13.
- A shut-off for the fuel and electrical power supply to the cooking equipment shall be provided in a location that is accessible only to staff.
- A timer shall be provided that automatically deactivates the cooking appliances within a period of not more than 120 minutes.
- A portable fire extinguisher shall be provided. Installation shall be in accordance with Section 906, and the extinguisher shall be located within a 30-foot (9144 mm) distance of travel from each domestic cooking appliance.
Related Code Sections
407.2.6 Special Detailed Requirements Based on Occupancy and Use, Nursing Home Cooking Facilities
In Group I-2, Condition 1 occupancies, rooms or spaces that contain a cooking facility with domestic cooking appliances shall be permitted to be open ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.2 Corridors Continuity and Separation > 407.2.6 Nursing Home Cooking Facilities
407.2.6 Special Detailed Requirements Based on Occupancy and Use, Nursing Home Cooking Facilities
In Group I-2, Condition 1 occupancies, rooms or spaces that contain a cooking facility with domestic cooking appliances shall be permitted to be open ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 407 Group I-2 > 407.2 Corridors Continuity and Separation > 407.2.6 Nursing Home Cooking Facilities
3.3.62 Definitions, Dwelling Unit (For Sprinkler System Installations)
in nursing homes, and similar living units ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 3 Definitions > 3.3 General Definitions > 3.3.62 Dwelling Unit (For Sprinkler System Installations)
517.40 Special Occupancies, Type 2 Essential Electrical Systems for Nursing Homes and Limited Care Facilities
Informational Note: Nursing homes and other limited care facilities can be classified as critical care (Category 1) or general care (Category 2 ...
National Electrical Code 2017 of Illinois > 5 Special Occupancies > 517 Health Care Facilities > 517.40 Type 2 Essential Electrical Systems for Nursing Homes and Limited Care Facilities
308.3.1.1 Occupancy Classification and Use, Condition 1
or in-patient stabilization units for psychiatric or detoxification, including but not limited to nursing homes and foster care facilities ...
Building Code 2021 of Illinois > 3 Occupancy Classification and Use > 308 Institutional Group I > 308.3 Institutional Group I-2 > 308.3.1 Occupancy Conditions > 308.3.1.1 Condition 1