8.3.13.5.4 Number of Tests
JUMP TO FULL CODE CHAPTER
Three tests shall be made with the maximum load called for, and three tests with the minimum load called for.
The time delay between two consecutive tests shall be not less than 5 min and not more than 30 min. In each of the three tests with maximum load, the value of reference of the buffer force at a stroke equal to 50% of the real height of the buffer given by the applicant shall not vary by more than 5%. For the tests with minimum load, the same procedure shall be followed.
Related Code Sections
8.3.13.5.4 General Requirements, Number of Tests
Three tests shall be made with the maximum load called for, and three tests with the minimum load called for. The time delay between two consecutive ...
Safety Code for Elevators and Escalators 2019 of Colorado > 8 General Requirements > 8.3 Engineering Tests, Type Tests, and Certification > 8.3.13 Type Tests of Elastomeric Buffers > 8.3.13.5 Test Procedure > 8.3.13.5.4 Number of Tests
A106.2.3.4 : Guidelines for the Seismic Retrofit of Existing Buildings, Number of Tests
The minimum number of tests per masonry class shall be determined as follows: At each of both the first and top stories, not less than two tests ...
Existing Building Code 2018 of Colorado > A : Guidelines for the Seismic Retrofit of Existing Buildings > A106 Materials Requirements > A106.2 Existing Unreinforced Masonry > A106.2.3 Testing of Masonry > A106.2.3.4 Number of Tests
A106.2.3.5 Guidelines for the Seismic Retrofit of Existing Buildings, Number of Tests
The minimum number of tests per masonry class shall be determined as follows: At each of both the first and top stories, not less than two tests ...
Existing Building Code 2021 of Colorado > A Guidelines for the Seismic Retrofit of Existing Buildings > A106 Materials Requirements > A106.2 Existing Unreinforced Masonry > A106.2.3 Testing of Masonry > A106.2.3.5 Number of Tests
A106.3.3.4 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Number of Tests
The minimum number of tests per class shall be as follows: At each of both the first and top stories, not less than two tests per wall or line ...
Existing Building Code 2015 of Colorado > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A106 Materials Requirements > A106.3 Existing Unreinforced Masonry > A106.3.3 Testing of Masonry > A106.3.3.4 Number of Tests
8.10.1.1.5 General Requirements, Acceptance Test Records
A permanent test record showing the test dates, the requirement number for each test, the name of the person or firm performing the test ...
Safety Code for Elevators and Escalators 2013 of Colorado > 8 General Requirements > 8.10 Acceptance Inspections and Tests > 8.10.1 General Requirements for Acceptance Inspections and Tests > 8.10.1.1 Persons Authorized to Make Acceptance Inspections and Tests > 8.10.1.1.5 Acceptance Test Records