504.4 Number of stories

California Building Code 2016 (Vol 1) > 5 General Building Heights and Areas > 504 Building Height and Number of Stories > 504.4 Number of stories
JUMP TO FULL CODE CHAPTER

The maximum number of stories of a building shall not exceed the limits specified in Table 504.4.

TABLE 504.4a, b, n

ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE

OCCUPANCY
CLASSIFICATION
TYPE OF CONSTRUCTION
SEE FOOTNOTESTYPE ITYPE IITYPE IIITYPE IVTYPE V
ABABABHTAB
A-1NSUL53232321
S (without area increase)UL64343432
S (with area increase)UL53232321
A-2NSUL113232321
S (without area increase)UL124343432
S (with area increase)UL113232321
A-3NSUL113232321
S (without area increase)UL124343432
S (with area increase)UL113232321
A-4NSUL113232321
S (without area increase)UL124343432
S (with area increase)UL113232321
A-5NSULULULULULULULULUL
SULULULULULULULULUL
BNSUL115353532
SUL126464643
ENSUL53232311
S (without area increase)UL64343422
S (with area increase)UL53232311
F-1NSUL114232421
SUL125343532
F-2NSUL115343532
SUL126454643
H-1NSc, d11111111NP
S
H-2NSc, d2032121211
S
H-3NSc, d2064242421
S
H-4NSc, d2075353532
S (without area increase)2086464643
S (with area increase)2075353532
H-5NSc, d443333332
S
I-2/I-2.1j, iNSd, fUL4211NP11NP
S (without area increase)UL53
S (with area increase)UL42
I-3NSd, eNPNPNPNPNPNPNPNPNP
S (without area increase)UL3NPNPNPNPNPNPNP
S (with area increase)UL2NPNPNPNPNPNPNP
I-4NSd, gUL53232311
S (without area increase)UL64343422
S (with area increase)UL53232311
LNSNPNPNPNPNPNPNPNPNP
S2065353532
MNSUL114242431
SUL125353542
R-1hNSdUL114444432
S13R4432
S (without area increase)UL125555543
S (with area increase)UL114444432
R-2hNSdUL114444432
S13R44432
S (without area increase)UL125555543
S (with area increase)UL11444444o2
R-2.1hNSdUL6l3kNP3kNPNP3kNP
S13RUL4l3kNP3kNPNP3kNP
SUL6l3kNP3kNPNP3kNP
R-3, R-3.1hNSdUL1133
S13D444444433
S13R4444
SUL125555544
R-4hNSdUL11l
S13D44l4k4m4k4m4m3k2m
S13R44l
SUL11l
S-1NSUL114232431
SUL125343542
S-2iNSUL115343442
SUL126454553
UNSUL54232421
SUL65343532

Note: UL = Unlimited; NP = Not Permitted; NS = Buildings not equipped throughout with an automatic sprinkler system; S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3.

  1. See Chapters 4 and 5 for specific exceptions to the allowable height in this chapter.
  2. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies.
  3. New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5.
  4. The NS value is only for use in evaluation of existing building height in accordance with the California Existing Building Code.
  5. New Group I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6.
  6. New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6 and Section 1103.5 of the California Fire Code.
  7. For new Group I-4 occupancies, see Exceptions 2 and 3 of Section 903.2.6.
  8. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8.
  9. See Sections 407.1.1 and 408.1.2 for specific exceptions to construction type, allowable building areas and allowable heights.
  10. Restraint shall not be permitted in any building except in Group I-3 occupancies constructed for such use (see Section 408.1.2).
  11. Nonambulatory persons shall be limited to the first 2 stories.
  12. Nonambulatory persons shall be limited to the first 5 stories.
  13. Nonambulatory elderly clients are not permitted in buildings of these types of construction. See Sections 435.3.3 and 435.3.4.
  14. In other than Group A, E, H, I, L, and R occupancies, high-rise buildings, and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, the S increases for height and stories in Tables 504.3 and 504.4 are permitted in addition to the S area increase in accordance with Table 506.2.
  15. For Group R-2 buildings of Type VA construction equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, S area increase is permitted in addition to the height and story increase provided the height shall not exceed 60 feet and 4 stories.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


2109.2.4.1 Masonry, Number of stories
Adobe construction shall be limited to buildings not exceeding one story , except that two- story construction is allowed where designed ...
California Building Code 2019 (Vol 1 & 2) > 21 Masonry > 2109 Empirical Design of Adobe Masonry > 2109.2 Adobe construction > 2109.2.4 Detailed requirements > 2109.2.4.1 Number of stories
2109.3.4.1 Masonry, Number of stories
Adobe construction shall be limited to buildings not exceeding one story, except that two-story construction is allowed when designed by a registered ...
California Building Code 2016 (Vol 2) > 21 Masonry > 2109 Empirical Design of Masonry > 2109.3 Adobe construction > 2109.3.4 Detailed requirements > 2109.3.4.1 Number of stories
504.4 General Building Heights and Areas, Number of stories
The maximum number of stories of a building shall not exceed the limits specified in Table 504.4. TABLE 504.4 a, b, n ALLOWABLE NUMBER OF ...
California Building Code 2016 (Vol 1) > 5 General Building Heights and Areas > 504 Building Height and Number of Stories > 504.4 Number of stories
Section 504 General Building Heights and Areas, Building Height and Number of Stories
The height, in feet, and the number of stories of a building shall be determined based on the type of construction, occupancy classification ...
California Building Code 2019 (Vol 1 & 2) > 5 General Building Heights and Areas > 504 Building Height and Number of Stories
508.4.3 General Building Heights and Areas, Allowable building height and number of stories
Each separated occupancy shall comply with the building height limitations and story limitations based on the type of construction ...
California Building Code 2019 (Vol 1 & 2) > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy > 508.4 Separated occupancies > 508.4.3 Allowable building height and number of stories
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US