// CODE SNIPPET
3116B.2 Number of Sanitary Facilities
JUMP TO FULL CODE CHAPTER
For the purpose of this subsection, one pool user shall be considered for every 15 square feet (1.39 m2) of pool water surface area and/or spray ground splash zone area.
One shower shall be provided for every 50 pool users.
Separate toilet facilities shall be provided for each sex. One toilet shall be provided for every 60 women or less and one toilet plus one urinal for every 75 men or less.
One lavatory shall be provided for every 80 pool users.
Related Code Sections
3116B.2 [DPH] Public Pools, Number of Sanitary Facilities
facilities shall be provided for each sex. One toilet shall be provided for every 60 women or less and one toilet plus one urinal for every 75 men or less ...
California Building Code 2016 (Vol 1 & 2) > 31B [DPH] Public Pools > 3116B Dressing, Shower and Toilet Facilities > 3116B.2 Number of Sanitary Facilities
3116B.2 [DPH] Public Pools, Number of Sanitary Facilities
Separate toilet facilities shall be provided
for each sex. One toilet shall be provided for every
60 women or less and one toilet plus one urinal ...
California Building Code 2019 (Vol 1 & 2) > 31B [DPH] Public Pools > 3116B Dressing, Shower and Toilet Facilities > 3116B.2 Number of Sanitary Facilities
3116B.2.1 [DPH] Public Pools, Showers
One shower shall be provided for
every 50 pool users ...
California Building Code 2019 (Vol 1 & 2) > 31B [DPH] Public Pools > 3116B Dressing, Shower and Toilet Facilities > 3116B.2 Number of Sanitary Facilities > 3116B.2.1 Showers
3116B.2.2 [DPH] Public Pools, Toilets
Separate toilet facilities shall be provided
for each sex. One toilet shall be provided for every
60 women or less and one toilet plus one urinal ...
California Building Code 2019 (Vol 1 & 2) > 31B [DPH] Public Pools > 3116B Dressing, Shower and Toilet Facilities > 3116B.2 Number of Sanitary Facilities > 3116B.2.2 Toilets
3116B.2.3 [DPH] Public Pools, Lavatories
One lavatory shall be provided for
every 80 pool users ...
California Building Code 2019 (Vol 1 & 2) > 31B [DPH] Public Pools > 3116B Dressing, Shower and Toilet Facilities > 3116B.2 Number of Sanitary Facilities > 3116B.2.3 Lavatories