Pools shall have toilet facilities with the number of fixtures in accordance with Section 609.2.1 or 609.2.2.
609.2.1 Water Area Less Than 7500 Square Feet
Facilities that have less than 7500 gross square feet (697 m2) of water area available for bather access shall have not less than one water closet for males, one urinal for males, one lavatory for males, one shower for males, two water closets for females, one lavatory for females and one shower for females.
609.2.2 Water Area 7500 Square Feet or More
Facilities that have 7500 gross square feet (697 m2) or more of water area available for bather access shall have not less than 0.7 water closet for males, one urinal for males, 0.85 lavatory for males, one shower for males, two water closets for females, one lavatory for females and one shower for females for every 7500 square feet (697 m2) or portion thereof. Where the result of the fixture calculation is a portion of a whole number, the result shall be rounded up to the nearest whole number.

Related Code Sections

2902.1 Plumbing Systems, Minimum Number of Fixtures
Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 2902.1. Types of occupancies not shown ...
2902.1 Plumbing Systems, Minimum Number of Fixtures
Plumbing fixtures shall be provided in the minimum number as shown in Table 2902.1 based on the actual use of the building or space. Uses not shown ...
2902.1 Plumbing Systems, Minimum Number of Fixtures
Plumbing fixtures shall be provided in the minimum number as shown in Table 2902.1 based on the actual use of the building or space. Uses not shown ...
403.1 Fixtures, Faucets and Fixture Fittings, Minimum Number of Fixtures
Plumbing fixtures shall be provided in the minimum number as shown in Table 403.1, based on the actual use of the building or space. Uses not shown ...