• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3002.2 Number of Elevator Cars in a Hoistway

Building Code 2021 of Illinois > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.2 Number of Elevator Cars in a Hoistway
JUMP TO FULL CODE CHAPTER
Where four or more elevator cars serve all or the same portion of a building, the elevators shall be located in not fewer than two separate hoistways. Not more than four elevator cars shall be located in any single hoistway enclosure.

Related Code Sections


3002.2 Elevators and Conveying Systems, Number of Elevator Cars in a Hoistway
Where four or more elevator cars serve all or the same portion of a building, the elevators shall be located in not fewer than two separate hoistways ...
Building Code 2021 of Illinois > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.2 Number of Elevator Cars in a Hoistway
3002.2 Elevators and Conveying Systems, Number of Elevator Cars in a Hoistway
Where four or more elevator cars serve all or the same portion of a building, the elevators shall be located in not fewer than two separate hoistways ...
Building Code 2018 of Illinois > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.2 Number of Elevator Cars in a Hoistway
8.7.2.1.2 General Requirements, Addition of an Elevator to an Existing Hoistway
Where an elevator is added to an existing hoistway, the number of elevators in that multiple hoistway shall be in accordance with the requirements ...
Safety Code for Elevators and Escalators 2019 of Illinois > 8 General Requirements > 8.7 Alterations > 8.7.2 Alterations to Electric Elevators > 8.7.2.1 Hoistway Enclosures > 8.7.2.1.2 Addition of an Elevator to an Existing Hoistway
620.54 Special Equipment, Heating and Air-Conditioning Disconnecting Means
than one elevator car in the machine room, the disconnecting means shall be numbered to correspond to the identifying number of the elevator car ...
National Electrical Code 2020 of Illinois > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.54 Heating and Air-Conditioning Disconnecting Means
911.1.6 Fire Protection and Life Safety Systems, Required Features
; elevator information that includes: number of elevator banks, elevator bank designation, elevator car numbers and respective floors that they serve ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 911 Fire Command Center > 911.1 General > 911.1.6 Required Features
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING