• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

221.2.1 Number and Location

2010 ADA Standards > 2 Scoping Requirements > 221 Assembly Areas > 221.2 Wheelchair Spaces > 221.2.1 Number and Location
JUMP TO FULL CODE CHAPTER
Wheelchair spaces shall be provided complying with 221.2.1.

221.2.1.1 General Seating

Wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1.
Table 221.2.1.1 Number of Wheelchair Spaces in Assembly Areas
Number of SeatsMinimum Number of Required Wheelchair Spaces
4 to 25 1
26 to 50 2
51 to 150 4
151 to 300 5
301 to 500 6
501 to 5000 6, plus 1 for each 150,
or fraction thereof, between 501 through 5000
5001 and over 36, plus 1 for each 200,
or fraction thereof, over 5000

221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands

In each luxury box, club box, and suite within arenas, stadiums, and grandstands, wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1.
Advisory 221.2.1.2 Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands.  The number of wheelchair spaces required in luxury boxes, club boxes, and suites within an arena, stadium, or grandstand is to be calculated box by box and suite by suite.

221.2.1.3 Other Boxes

In boxes other than those required to comply with 221.2.1.2, the total number of wheelchair spaces required shall be determined in accordance with Table 221.2.1.1.  Wheelchair spaces shall be located in not less than 20 percent of all boxes provided.  Wheelchair spaces shall comply with 802.1.
Advisory 221.2.1.3 Other Boxes.  The provision for seating in "other boxes" includes box seating provided in facilities such as performing arts auditoria where tiered boxes are designed for spatial and acoustical purposes.  The number of wheelchair spaces required in boxes covered by 221.2.1.3 is calculated based on the total number of seats provided in these other boxes.  The resulting number of wheelchair spaces must be located in no fewer than 20% of the boxes covered by this section.  For example, a concert hall has 20 boxes, each of which contains 10 seats, totaling 200 seats.  In this example, 5 wheelchair spaces would be required, and they must be placed in at least 4 of the boxes. Additionally, because the wheelchair spaces must also meet the dispersion requirements of 221.2.3, the boxes containing these wheelchair spaces cannot all be located in one area unless an exception to the dispersion requirements applies.

221.2.1.4 Team or Player Seating

At least one wheelchair space complying with 802.1 shall be provided in team or player seating areas serving areas of sport activity.

EXCEPTION: Wheelchair spaces shall not be required in team or player seating areas serving bowling lanes not required to comply with 206.2.11.

Related Code Sections


221.2.1 Scoping Requirements, Number and Location
on the total number of seats provided in these other boxes.  The resulting number of wheelchair spaces must be located in no fewer than 20% of the boxes ...
2010 ADA Standards > 2 Scoping Requirements > 221 Assembly Areas > 221.2 Wheelchair Spaces > 221.2.1 Number and Location
707.6.2 Communication Elements and Features, Numeric Keys
descending numerical order.  Both types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located ...
2010 ADA Standards > 7 Communication Elements and Features > 707 Automatic Teller Machines and Fare Machines > 707.6 Input > 707.6.2 Numeric Keys
707 Communication Elements and Features, Automatic Teller Machines and Fare Machines
to complete or verify the transaction. EXCEPTIONS : Machine location, date and time of transaction, customer account number, and the machine ...
2010 ADA Standards > 7 Communication Elements and Features > 707 Automatic Teller Machines and Fare Machines
233.3.1 Scoping Requirements, Minimum Number: New Construction
residential dwelling units, the requirements of 233.3.1.1 and 233.3.1.2 shall apply to the total number of residential dwelling units that are constructed ...
2010 ADA Standards > 2 Scoping Requirements > 233 Residential Facilities > 233.3 Residential Dwelling Units Provided by Entities Not Subject to HUD Section 504 Regulations > 233.3.1 Minimum Number: New Construction
707.5.2 Communication Elements and Features, Receipts
on the printed receipt necessary to complete or verify the transaction. EXCEPTIONS : Machine location, date and time of transaction, customer ...
2010 ADA Standards > 7 Communication Elements and Features > 707 Automatic Teller Machines and Fare Machines > 707.5 Speech Output > 707.5.2 Receipts
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING