802.8.3 Nuisance and Hazard
JUMP TO FULL CODE CHAPTER
Through-the-wall vents for Category II and Category IV appliances and noncategorized
condensing appliances shall not terminate over
public walkways or over an area where condensate or vapor
is capable of creating a nuisance or hazard that is detrimental
to the operation of regulators, relief valves, or other
equipment. Where local experience indicates that condensate
is a problem with Category I and Category III appliances,
this provision shall apply.
Drains for condensate shall be installed in accordance with the appliance and the vent manufacturer's installation instructions. [NFPA 54:12.9.4]
Drains for condensate shall be installed in accordance with the appliance and the vent manufacturer's installation instructions. [NFPA 54:12.9.4]
Related Code Sections
509.8.3 Water Heaters, Nuisance and Hazard
or over an area where condensate or
vapor is capable of creating a nuisance or hazard detrimental
to the operation of regulators, relief valves ...
California Plumbing Code 2016 > 5 Water Heaters > 509.0 Venting of Appliances > 509.8 Through-The-Wall Vent Termination > 509.8.3 Nuisance and Hazard
802.8.3 Chimneys and Vents, Nuisance and Hazard
or over an area where condensate or vapor
is capable of creating a nuisance or hazard that is detrimental
to the operation of regulators, relief valves ...
California Mechanical Code 2016 > 8 Chimneys and Vents > 802.0 Venting of Appliances > 802.8 Through-The-Wall Vent Termination > 802.8.3 Nuisance and Hazard
509.8.3 Water Heaters, Category I Through Category IV and Non-Categorized Appliances
or over an area where condensate or
vapor could create a nuisance or hazard or could be detrimental
to the operation of regulators, relief valves ...
California Plumbing Code 2019 > 5 Water Heaters > 509.0 Venting of Appliances > 509.8 Through-The-Wall Vent Termination > 509.8.3 Category I Through Category IV and Non-Categorized Appliances
802.8.3 Chimneys and Vents, Category I Through Category IV and Noncategorized Appliances
or over an area where condensate or
vapor could create a nuisance or hazard or could be detrimental to the operation of regulators, relief valves ...
California Mechanical Code 2019 > 8 Chimneys and Vents > 802.0 Venting of Appliances > 802.8 Through-The-Wall Vent Termination > 802.8.3 Category I Through Category IV and Noncategorized Appliances
304.2 General Requirements, Storage
Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare ...