• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1226.11.2.8 Nourishment Room or Area

California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.11 Alternative Birthing Clinics > 1226.11.2 Support Areas for Birthing Services > 1226.11.2.8 Nourishment Room or Area
JUMP TO FULL CODE CHAPTER
When provided, refer to Section 1226.4.13.7.

Related Code Sections


1226.11.2.8 Interior Environment, Nourishment Room or Area
When provided, refer to Section 1226.4.13.7 ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.11 Alternative Birthing Clinics > 1226.11.2 Support Areas for Birthing Services > 1226.11.2.8 Nourishment Room or Area
1226.11.2.8 Interior Environment, Nourishment Room or Area
When provided, refer to Section 1226.4.13.7 ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.11 Alternative Birthing Clinics > 1226.11.2 Support Areas for Birthing Services > 1226.11.2.8 Nourishment Room or Area
1226.4.13.7 Interior Environment, Nourishment Room
When provided, the nourishment room or area shall have all of the following: Sink Work counter Refrigerator Storage cabinets ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.4 General Construction > 1226.4.13 Support Areas for Examination and Treatment Rooms > 1226.4.13.7 Nourishment Room
1225.5.2.4.9 Interior Environment, Nourishment Room
A nourishment room or area for serving nourishments between meals shall be provided and shall contain a work counter, refrigerator, storage cabinets ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1225 [OSHPD 2] Skilled Nursing and Intermediate-Care Facilities > 1225.5 Skilled Nursing Unit Models > 1225.5.2 Household Model > 1225.5.2.4 Resident Support Area > 1225.5.2.4.9 Nourishment Room
1225.5.2.4.9 Interior Environment, Nourishment Room
A nourishment room or area for serving nourishments between meals shall be provided and shall contain a work counter, refrigerator, storage cabinets ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1225 [OSHPD 2] Skilled Nursing and Intermediate-Care Facilities > 1225.5 Skilled Nursing Unit Models > 1225.5.2 Household Model > 1225.5.2.4 Resident Support Area > 1225.5.2.4.9 Nourishment Room
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING