• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3304.3.2 Notification of Adjacent Building Owners

NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3304 Excavation > 3304.3 Notification > 3304.3.2 Notification of Adjacent Building Owners
JUMP TO FULL CODE CHAPTER
When an excavation to a depth of 5 to 10 feet (1524 mm to 3048 mm) is to be made within 10 feet (3048 mm) of an adjacent building, or when any excavation over 10 feet (3048 mm) is to be made anywhere on the site, the person causing an excavation to be made shall provide written notice to the owners of the adjacent building or buildings not less than 10 days prior to the scheduled starting date of the excavation. The written notice shall provide a description of the work to be performed, the time frame and schedule, and contact information of the person causing the excavation and of the department. Foundation or earthwork that is to be done with the use of explosives shall also be subject to the notification requirements set forth in Sections 3307.5.3 and 3307.5.4 of the New York City Fire Code.

*Section BC 3304.3.2 was amended by: Local Law 26 of 2008 — Update Page #3. This law has an effective date of July 01, 2008.

Related Code Sections


3304.3.2 Safeguards During Construction or Demolition, Notification of Adjacent Building Owners
When an excavation to a depth of 5 to 10 feet (1524 mm to 3048 mm) is to be made within 10 feet (3048 mm) of an adjacent building, or when any ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3304 Excavation > 3304.3 Notification > 3304.3.2 Notification of Adjacent Building Owners
3306.3 Safeguards During Construction or Demolition, Notification
Notification to the department or adjoining owners is not required for partial demolition that occurs on the exterior of a building, provided ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.3 Notification
§28-324.3.2 Maintenance of Buildings, Notification
established by the department. Such notification shall not relieve the applicant, owner, engineer, architect or contractor of the obligation to comply ...
NYC General Admin. Provisions 2022 > 3 Maintenance of Buildings > 324 Periodic Inspections of Dry Floodproofing > §28-324.3 Triennial Full-Scale Deployment Inspection > §28-324.3.2 Notification
3306.3 Safeguards During Construction or Demolition, Notification
, are used. Notification to the department or adjoining property owners is not required for partial demolition that occurs on the exterior of a building ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.3 Notification
3304.3 Safeguards During Construction or Demolition, Notification
Prior to the commencement of soil or foundation work, notification shall be provided as follows ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.3 Notification
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING