Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[BS] A113.8 Nonstructural Masonry Walls

Existing Building Code 2015 of Idaho > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A113 Detailed System Design Requirements > A113.8 Nonstructural Masonry Walls
JUMP TO FULL CODE CHAPTER
Unreinforced masonry walls that carry no design vertical or lateral loads and that are not required by the design to be part of the lateral force-resisting system shall be adequately anchored to new or existing supporting elements. The anchors and elements shall be designed for the out-of-plane forces specified in the building code. The height- or length-to-thickness ratio between such supporting elements for such walls shall not exceed nine.

Related Code Sections


A113.8 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings, Nonstructural Masonry Walls
Unreinforced masonry walls that carry no design vertical or lateral loads and that are not required by the design to be part of the lateral force ...
Existing Building Code 2015 of Idaho > A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings > A113 Detailed System Design Requirements > A113.8 Nonstructural Masonry Walls
906.7 Alterations—Level 3, Anchorage of Unreinforced Masonry Partitions
Where the building is assigned to Seismic Design Category C, D, E or F, unreinforced masonry partitions and nonstructural walls within the work area ...
Existing Building Code 2018 of Idaho > 9 Alterations—Level 3 > 906 Structural > 906.7 Anchorage of Unreinforced Masonry Partitions
503.10 Prescriptive Compliance Method, Anchorage of Unreinforced Masonry Partitions in Major Alterations
, unreinforced masonry partitions and nonstructural walls within the work area and adjacent to egress paths from the work area shall be anchored, removed ...
Existing Building Code 2018 of Idaho > 5 Prescriptive Compliance Method > 503 Alterations > 503.10 Anchorage of Unreinforced Masonry Partitions in Major Alterations
2103.1 Masonry, Masonry Units
Exception: Structural clay tile for nonstructural use in fireproofing of structural members and in wall furring shall not be required to meet ...
Building Code 2018 of Idaho > 21 Masonry > 2103 Masonry Construction Materials > 2103.1 Masonry Units
1805.3.2 Soils and Foundations, Walls
Walls required to be waterproofed shall be of concrete or masonry and shall be designed and constructed to withstand the hydrostatic pressures ...
Building Code 2015 of Idaho > 18 Soils and Foundations > 1805 Dampproofing and Waterproofing > 1805.3 Waterproofing > 1805.3.2 Walls
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.