8-706.5 Nonstructural Features
JUMP TO FULL CODE CHAPTER
Nonstructural features of historical structure, such as exterior veneer, cornices and decorations, which might fall and create a life-safety hazard in an earthquake, shall be evaluated. Their ability to resist seismic forces shall be verified, or the feature shall be strengthened with improved anchorage when appropriate.
Partitions and ceilings of corridors and stairways serving an occupant load of 30 or more shall be investigated to determine their ability to remain in place when the building is subjected to earthquake forces.
Seismic forces used to evaluate and improve nonstructural components and their anchorage, where required, shall comply with ASCE 41 or need not exceed 0.75 times the seismic forces prescribed by the requirements of the regular code.
Related Code Sections
8-706.5 Structural Regulations, Nonstructural Features
Nonstructural features of historical structure, such as exterior veneer, cornices and decorations, which might fall and create a life-safety hazard ...
California Historical Building Code 2016 > 8-7 Structural Regulations > 8-706 Lateral Load Regulations > 8-706.5 Nonstructural Features
8-706.5 Structural Regulations, Nonstructural Features
Nonstructural features of historical structure, such as exterior veneer, cornices and decorations, which might fall and create a life-safety hazard ...
California Historical Building Code 2019 > 8-7 Structural Regulations > 8-706 Lateral Load Regulations > 8-706.5 Nonstructural Features
1005.7.2 Means of Egress, Other Projections
Handrail projections shall be in accordance with the provisions of Section 1014.8. Other nonstructural projections such as trim and similar ...
California Building Code 2016 (Vol 1 & 2) > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.7 Encroachment > 1005.7.2 Other Projections
Section 8-706 Structural Regulations, Lateral Load Regulations
to life safety. Nonstructural features of historical ...
California Historical Building Code 2019 > 8-7 Structural Regulations > 8-706 Lateral Load Regulations
1005.7.2 Means of Egress, Other Projections
Handrail projections shall be in accordance with the provisions of Section 1014.8. Other nonstructural projections such as trim and similar ...
California Fire Code 2019 > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.7 Encroachment > 1005.7.2 Other Projections