Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1705.13.2 Nonstructural Components

Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.13 Testing for Seismic Resistance > 1705.13.2 Nonstructural Components
JUMP TO FULL CODE CHAPTER
For structures assigned to Seismic Design Category B, C, D, E or F, where the requirements of Section 13.2.1 of ASCE 7 for nonstructural components, supports or attachments are met by seismic qualification as specified in Item 2 therein, the registered design professional shall specify on the approved construction documents the requirements for seismic qualification by analysis, testing or experience data. Certificates of compliance for the seismic qualification shall be submitted to the building official as specified in Section 1704.5.

Related Code Sections


1705.13.2 Special Inspections and Tests, Nonstructural Components
For structures assigned to Seismic Design Category B, C, D, E or F, where the requirements of Section 13.2.1 of ASCE 7 for nonstructural components ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.13 Testing for Seismic Resistance > 1705.13.2 Nonstructural Components
1705.14.2 Special Inspections and Tests, Nonstructural Components
For structures assigned to Seismic Design Category B, C, D, E or F, where the requirements of Section 13.2.1 of ASCE 7 for nonstructural components ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.14 Testing for Seismic Resistance > 1705.14.2 Nonstructural Components
18.10.7.2 Earthquake-Resistant Structures,
of the structure, the egress from the structure, or the integrity of nonstructural components and their connections to the structure ...
Building Code Requirements for Structural Concrete of Illinois > 18 Earthquake-Resistant Structures > 18.10 Special Structural Walls > 18.10.7 Coupling Beams > 18.10.7.2
18.10.7.2 Earthquake-Resistant Structures,
load-carrying ability of the structure, the egress from the structure, or the integrity of nonstructural components and their connections ...
Building Code Requirements for Structural Concrete of Illinois > 18 Earthquake-Resistant Structures > 18.10 Special Structural Walls > 18.10.7 Coupling Beams > 18.10.7.2
1613.3 Structural Design, Ballasted Photovoltaic Panel Systems
, using input motions consistent with ASCE 7 lateral and vertical seismic forces for nonstructural components on roofs ...
Building Code 2021 of Illinois > 16 Structural Design > 1613 Earthquake Loads > 1613.3 Ballasted Photovoltaic Panel Systems
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING