• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5104.3.1 Nonsegregated Storage

Fire Code 2021 of Colorado > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.3 Storage in General Purpose Warehouses > 5104.3.1 Nonsegregated Storage
JUMP TO FULL CODE CHAPTER
Storage consisting of solid pile, palletized or rack storage of Level 2 and 3 aerosol products not segregated into areas utilized exclusively for the storage of aerosol products shall comply with Table 5104.3.1.
TABLE 5104.3.1
NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSESb
AEROSOL LEVEL MAXIMUM NET WEIGHT PER FLOOR (pounds)b
Palletized or solid-pile storage Rack storage
Unprotected Protecteda Unprotected Protecteda
2 2,500 12,000 2,500 24,000
3 1,000 12,000 1,000 24,000
Combination 2 and 3 2,500 12,000 2,500 24,000
For SI: 1 foot = 304.8 mm, 1 pound = 0.454 kg, 1 square foot = 0.0929 m2.
  1. Approved automatic sprinkler system protection and storage arrangements shall comply with NFPA 30B. Sprinkler system protection shall extend 20 feet beyond the storage area containing the aerosol products.
  2. Storage quantities indicated are the maximum permitted in any 50,000-square-foot area.

Related Code Sections


5104.3.1 Aerosols, Nonsegregated Storage
for the storage of aerosol products shall comply with Table 5104.3.1. TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL ...
Fire Code 2021 of Colorado > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.3 Storage in General Purpose Warehouses > 5104.3.1 Nonsegregated Storage
5104.3.1 Aerosols, Nonsegregated Storage
for the storage of aerosol products shall comply with Table 5104.3.1. TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL ...
Fire Code 2018 of Colorado > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.3 Storage in General Purpose Warehouses > 5104.3.1 Nonsegregated Storage
Section 5104 Aerosols, Inside Storage of Aerosol Products
exclusively for the storage of aerosol products shall comply with Table 5104.3.1. TABLE 5104.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS ...
Fire Code 2018 of Colorado > 51 Aerosols > 5104 Inside Storage of Aerosol Products
1002.4 Change of Occupancy, Storage
Code , where a room 250 square feet (23.2 m 2 ) or less undergoes a change in occupancy to a storage room, the room shall be separated from ...
Existing Building Code 2021 of Colorado > 10 Change of Occupancy > 1002 Special Use and Occupancy > 1002.4 Storage
1109.9 Accessibility, Storage
Where fixed or built-in storage elements such as cabinets, coat hooks, shelves, medicine cabinets, lockers, closets and drawers are provided ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 11 Accessibility > 1109 Other Features and Facilities > 1109.9 Storage
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING