• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

A5.209.7 Nonresidential Lighting Control Acceptance

California Green Building Standards Code 2019 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.209 [OSHPD 1, 2 & 4] Lighting > A5.209.7 Nonresidential Lighting Control Acceptance
JUMP TO FULL CODE CHAPTER
Before an occupancy permit is granted for a new building or space or a new lighting system serving a building, space or site is operated for normal use, all indoor and outdoor lighting controls serving the building, space or site shall be certified as meeting the Acceptance Requirements for Code Compliance. A Certificate of Acceptance shall be submitted to the enforcement agency under Section 10-103(a) of Title 24, Part 1, that:
  1. Certifies that plans, specifications, installation certificates and operating and maintenance information meet the requirements of Title 24, Part 6.
  2. Certifies that automatic daylighting controls meet the applicable requirements of Sections A5.209.1 and A5.209.2.3.2.4.
  3. Certifies that when a multilevel astronomical time switch is used to meet Exception 3 to Section A5.209.2.3.2.2 all general lighting in the skylit area is controlled by a multilevel astronomical time switch that meets the applicable requirements of Section A5.209.1 and that has an override switch that meets the requirements of Section A209.2.4.2.
  4. Certifies that lighting controls meet the requirements of Sections A5.209.2.1 through A5.209.2.3 and Title 24, Part 6, Sections 131(e) and (f) and 146(a)2, as applicable.
  5. Certifies that automatic lighting controls meet the applicable requirements of Sections A5.209.1 and A5.209.2.4.
  6. Certifies that occupant-sensors meet the applicable requirements of Sections A5.209.1 and A5.209.2.4.
  7. Certified that outdoor lighting controls meet the applicable requirements of Sections A5.209.1 and A5.209.3.

Related Code Sections


A5.209.7 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], Nonresidential Lighting Control Acceptance
use, all indoor and outdoor lighting controls serving the building, space or site shall be certified as meeting the Acceptance Requirements for Code ...
California Green Building Standards Code 2016 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.209 [OSHPD 1, 2 & 4] Lighting > A5.209.7 Nonresidential Lighting Control Acceptance
A5.209.7 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], Nonresidential Lighting Control Acceptance
use, all indoor and outdoor lighting controls serving the building, space or site shall be certified as meeting the Acceptance Requirements for Code ...
California Green Building Standards Code 2019 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.209 [OSHPD 1, 2 & 4] Lighting > A5.209.7 Nonresidential Lighting Control Acceptance
10-103.1 Administrative Regulations for the California Energy Commission (CEC), Nonresidential Lighting Controls Acceptance Test Training and Certification
(a) Scope. The requirements of this section apply to nonresidential lighting control Acceptance Test Technicians and Employers ...
California Administrative Code 2016 > 10 Administrative Regulations for the California Energy Commission (CEC) > 1 Energy Building Regulations > 10-103.1 Nonresidential Lighting Controls Acceptance Test Training and Certification
10-103.1 Administrative Regulations for the California Energy Commission (CEC), Nonresidential Lighting Controls Acceptance Test Training and Certification
Technician Certification Providers (ATTCPs) that perform work relating to the acceptance testing of nonresidential lighting systems and controls ...
California Administrative Code 2019 > 10 Administrative Regulations for the California Energy Commission (CEC) > 1 Energy Building Regulations > 10-103 Permit, Certificate, Informational and Enforcement Requirements for Designers, Installers, Builders, Manufacturers and Suppliers > 10-103.1 Nonresidential Lighting Controls Acceptance Test Training and Certification
Section 130.4 Nonresidential, High-Rise Residential and Hotel/Motel Occupancies—Mandatory Requirements for Lighting Systems and Equipment, and Electrical Power Distribution Systems, Lighting Control Acceptance and Installation Certificate Requirements
). (a) Lighting control acceptance requirements. Before an occupancy permit is granted, indoor and outdoor lighting controls serving the building ...
California Energy Code 2016 > 4 Nonresidential, High-Rise Residential and Hotel/Motel Occupancies—Mandatory Requirements for Lighting Systems and Equipment, and Electrical Power Distribution Systems > 130.4 Lighting Control Acceptance and Installation Certificate Requirements
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING