G304.1.2 Nonresidential
JUMP TO FULL CODE CHAPTER
For buildings or structures that are nonresidential (for flood zone purposes), all post-FIRM new buildings, horizontal enlargements and substantial improvements shall comply with the applicable requirements of this appendix and ASCE 24, and shall comply with either of the following:
- Elevation option. The structure shall comply with Items 1 through 7 of Section G304.1.1; or
- Dry floodproofing option. The structure shall comply with the following:
- Elevation of dry floodproofing. The structure shall be dry floodproofed to or above the design flood elevation specified in ASCE 24, Table 6-1;
- Dwelling units, patient care areas (for flood zone purposes) and sleeping areas. Where dwelling units, patient care areas (for flood zone purposes) or spaces intended to be used by persons for sleeping purposes are located in a building utilizing the dry floodproofing option, the following additional requirements shall be met:
- All rooms and spaces within dwelling units, patient care areas (for flood zone purposes) and all spaces intended to be used by persons for sleeping purposes shall be located at or above the design flood elevation;
- A restrictive declaration noting the above restriction shall be filed with the City Register or County Clerk, and the City Register File Number (CRFN) shall be identified in the permit application and on the certificate of occupancy.
- Utilities and equipment. Utilities and attendant equipment shall be located within the dry floodproofed enclosure, or may be located outside the dry floodproofed enclosure provided that they are located at or above the design flood elevation specified in ASCE 24, Table 7-1, or are constructed so as to prevent water from entering or accumulating within the components during conditions of flooding in accordance with ASCE 24.
- Additional requirements. Notwithstanding the above, utilities and attendant equipment, listed in Items 5.1 through 5.4 of Section G304.1.1, shall not be located in dry floodproofed enclosures and shall be elevated in accordance with Section G304.1.1.
- Fire department connections. Dry floodproofing measures including temporary shields, stairs and ramps shall be located and arranged so as to allow hose lines to be attached to the inlets of fire department connections without interference in accordance with Section 6.4.5 of NFPA 14, as modified by Appendix Q of this code.
- Certifications. Applications shall contain applicable certifications in accordance with Section G104.2.3; and
- Special inspections. Special inspections shall be as required by Section G107
Related Code Sections
G304.1.2 Flood-Resistant Construction, Nonresidential
For buildings or structures that are nonresidential (for flood zone purposes), all post-FIRM new buildings and substantial improvements shall comply ...
NYC Building Code 2014 > G Flood-Resistant Construction > G304 Post-Firm Construction and Substantial Improvements > G304.1 A-Zone Construction Standards > G304.1.2 Nonresidential
G304.1.2 Flood-Resistant Construction, Nonresidential
For buildings or structures that are nonresidential (for flood zone purposes), all post-FIRM new buildings and substantial improvements ...
NYC Building Code 2008 > G Flood-Resistant Construction > G304 Post-Firm Construction and Substantial Improvements > G304.1 A-Zone Construction Standards > G304.1.2 Nonresidential
G304.1.2 Flood-Resistant Construction, Nonresidential
For buildings or structures that are nonresidential (for flood zone purposes), all post-FIRM new buildings, horizontal enlargements and substantial ...
NYC Building Code 2022 > G Flood-Resistant Construction > G304 Post-Firm Construction, Horizontal Enlargements and Substantial Improvements > G304.1 A-Zone Construction Standards > G304.1.2 Nonresidential
607.1 Water Supply and Distribution, Where Required
, cleansing, laundry or building maintenance. In nonresidential occupancies, hot water shall be supplied to all plumbing fixtures and equipment utilized ...
NYC Plumbing Code 2008 > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required
607.1 Water Supply and Distribution, Where Required
, cleansing, laundry or building maintenance. In nonresidential occupancies, hot water shall be supplied for culinary purposes, cleansing, laundry ...
NYC Plumbing Code 2014 > 6 Water Supply and Distribution > 607 Hot Water Supply System > 607.1 Where Required