• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

52.2.2.1.1 Nonrecombinant Batteries

Fire Code 2018 of West Virginia > 52 Energy Storage Systems > 52.2* Lead-Acid and Nickel-Cadmium Batteries > 52.2.2 Safety Features > 52.2.2.1 Safety Venting > 52.2.2.1.1 Nonrecombinant Batteries
JUMP TO FULL CODE CHAPTER
Vented lead-acid and nickel-cadmium shall be provided with safety venting caps.

Related Code Sections


52.2.2.1.1 Energy Storage Systems, Nonrecombinant Batteries
Vented lead-acid and nickel-cadmium shall be provided with safety venting caps ...
Fire Code 2018 of West Virginia > 52 Energy Storage Systems > 52.2* Lead-Acid and Nickel-Cadmium Batteries > 52.2.2 Safety Features > 52.2.2.1 Safety Venting > 52.2.2.1.1 Nonrecombinant Batteries
720.9 Special Conditions, Batteries
Installations of storage batteries shall comply with 480.1 through 480.6 and 480.9 through 480.11 ...
National Electrical Code 2017 of West Virginia > 7 Special Conditions > 720 Circuits and Equipment Operating at Less Than 50 Volts > 720.9 Batteries
13.4.4.3 Fire Protection Systems, Battery Maintenance
Storage batteries shall be designed and installed so that they can be kept charged at all times. [ 20: 11.6.3.1 ...
Fire Code 2018 of West Virginia > 13 Fire Protection Systems > 13.4 Fire Pumps > 13.4.4* Diesel Engine Driver System Operation > 13.4.4.3 Battery Maintenance
(H) Wiring and Protection, Battery Conductors
Overcurrent protection shall be permitted to be installed as close as practicable to the storage battery terminals in an unclassified location ...
National Electrical Code 2017 of West Virginia > 2 Wiring and Protection > 240 Overcurrent Protection > 240.21 Location in Circuit > (H) Battery Conductors
28.1.3.2.4* Marinas, Boatyards, Marine Terminals, Piers, and Wharves, Battery Storage
Where due to size and weight the removal of batteries for storage or charging is impractical, batteries shall be permitted to remain onboard provided ...
Fire Code 2018 of West Virginia > 28 Marinas, Boatyards, Marine Terminals, Piers, and Wharves > 28.1 Marinas, Boatyards, and Other Recreational Marine Facilities > 28.1.3 Berthing and Storage > 28.1.3.2 Dry Storage > 28.1.3.2.4* Battery Storage
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING