Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

508.2.5.2 Nonfire-Resistance-Rated Separation and Protection

Building Code 2009 of Alabama > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy > 508.2 Accessory Occupancies > 508.2.5 Separation of Incidental Accessory Occupancies > 508.2.5.2 Nonfire-Resistance-Rated Separation and Protection
JUMP TO FULL CODE CHAPTER
Where Table 508.2.5 permits an automatic fire-extinguishing system without a fire barrier, the incidental accessory occupancies shall be separated from the remainder of the building by construction capable of resisting the passage of smoke. The walls shall extend from the top of the foundation or floor assembly below to the underside of the ceiling that is a component of a fire-resistance-rated floor assembly or roof assembly above or to the underside of the floor or roof sheathing, deck or slab above. Doors shall be self- or automatic- closing upon detection of smoke in accordance with Section 715.4.8.3. Doors shall not have air transfer openings and shall not be undercut in excess of the clearance permitted in accordance with NFPA 80. Walls surrounding the incidental accessory occupancy shall not have air transfer openings unless provided with smoke dampers in accordance with Section 711.7.

Related Code Sections


508.2.5.2 General Building Heights and Areas, Nonfire-Resistance-Rated Separation and Protection
or floor assembly below to the underside of the ceiling that is a component of a fire-resistance-rated floor assembly or roof assembly above ...
Building Code 2009 of Alabama > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy > 508.2 Accessory Occupancies > 508.2.5 Separation of Incidental Accessory Occupancies > 508.2.5.2 Nonfire-Resistance-Rated Separation and Protection
714.5 Fire and Smoke Protection Features, Nonfire-Resistance-Rated Assemblies
Penetrations of nonfire-resistance-rated floor or floor/ceiling assemblies or the ceiling membrane of a nonfire-resistance-rated roof/ceiling ...
Building Code 2015 of Alabama > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.5 Nonfire-Resistance-Rated Assemblies
714.6 Fire and Smoke Protection Features, Nonfire-Resistance-Rated Assemblies
Penetrations of nonfire-resistance-rated floor or floor/ceiling assemblies or the ceiling membrane of a nonfire-resistance-rated roof/ceiling ...
Building Code 2021 of Alabama > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.6 Nonfire-Resistance-Rated Assemblies
706.6.1 Fire and Smoke Protection Features, Stepped Buildings
inches (762 mm) above the lower roof shall be of not less than 1-hour fire-resistance-rated construction from both sides with openings protected ...
Building Code 2021 of Alabama > 7 Fire and Smoke Protection Features > 706 Fire Walls > 706.6 Vertical Continuity > 706.6.1 Stepped Buildings
713.4.2 Fire and Smoke Protection Features, Nonfire-Resistance-Rated Assemblies
Penetrations of nonfire-resistance-rated floor or floor/ceiling assemblies or the ceiling membrane of a nonfire-resistance- rated roof/ceiling ...
Building Code 2009 of Alabama > 7 Fire and Smoke Protection Features > 713 Penetrations > 713.4 Horizontal Assemblies > 713.4.2 Nonfire-Resistance-Rated Assemblies
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING