1027.7 Nonexit Door Identification
JUMP TO FULL CODE CHAPTER
Any door that is not an exit or otherwise part of the means of egress from a building, structure or premises, but which, by reason of its proximity or similar construction, can be confused with an exit door or other door that is part of the means of egress, shall be identified with an approved sign that reads "Not An Exit" and identifies the room into which the nonexit door provides access.
Related Code Sections
1007.6.5 Means of Egress, Identification
Each door providing access to an area of rescue assistance from an adjacent floor area shall be identified by a sign complying with ICC A117.1 ...
NYC Building Code 2008 > 10 Means of Egress > 1007 Accessible Means of Egress > 1007.6 Areas of Rescue Assistance > 1007.6.5 Identification
1006.5.2 Dwelling Units and Sleeping Units, Identification
A means for visually identifying a visitor without opening the unit entry door shall be provided. Peepholes, where used, shall provide a minimum 180 ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 10 Dwelling Units and Sleeping Units > 1006 Units With Accessible Communication Features > 1006.5 Unit Primary Entrance > 1006.5.2 Identification
Section 2.29 Electric Elevators, Identification
In buildings with more than one elevator, each elevator in the building shall be assigned a unique alphabetical or numerical identification ...
Safety Code for Elevators and Escalators 2013 of New York City > 2 Electric Elevators > 2.29 Identification
715.4.7.3.1 Fire and Smoke Protection Features, Identification
For fire protection-rated glazing, the label shall bear the following four-part identification: "D, H or NH, T or NT, XXX." "D" indicates ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 715 Opening Protectives > 715.4 Fire Door and Shutter Assemblies > 715.4.7 Glazing Material > 715.4.7.3 Labeling > 715.4.7.3.1 Identification
2.12.4.3 Electric Elevators, Identification Marking
Each listed/certified device shall be labeled. It shall be permanently attached to the device, and shall be so located as to be readily visible when ...
Safety Code for Elevators and Escalators 2013 of New York City > 2 Electric Elevators > 2.12 Hoistway Door Locking Devices and Electric Contacts, and Hoistway Accesss Switches > 2.12.4 Listing/Certification Door Locking Devices and Door or Gate Electric Contacts > 2.12.4.3 Identification Marking