Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1104.4.1 Noncommunicating Spaces

Mechanical Code 2018 of Maryland > 11 Refrigeration > 1104 System Application Requirements > 1104.4 Volume Calculations > 1104.4.1 Noncommunicating Spaces
JUMP TO FULL CODE CHAPTER
Where the refrigerant-containing parts of a system are located in one or more spaces that do not communicate through permanent openings or HVAC ducts, the volume of the smallest, enclosed occupied space shall be used to determine the permissible quantity of refrigerant in the system.

Related Code Sections


1104.4.1 Refrigeration, Noncommunicating Spaces
Where the refrigerant-containing parts of a system are located in one or more spaces that do not communicate through permanent openings or HVAC ducts ...
Mechanical Code 2018 of Maryland > 11 Refrigeration > 1104 System Application Requirements > 1104.4 Volume Calculations > 1104.4.1 Noncommunicating Spaces
R302.4.2 Building Planning, Membrane Penetrations
space between the wall membrane and the box shall not exceed 1 / 8 inch (3.1 mm). Such boxes on opposite sides of the wall shall be separated by one ...
Residential Code 2015 of Maryland > 3 Building Planning > R302 Fire-Resistant Construction > R302.4 Dwelling Unit Rated Penetrations > R302.4.2 Membrane Penetrations
R302.4.2 Building Planning, Membrane Penetrations
of the openings through the membrane does not exceed 100 square inches (0.0645 m 2 ) in any 100 square feet (9.29 m 2 ) of wall area. The annular space ...
Residential Code 2018 of Maryland > 3 Building Planning > R302 Fire-Resistant Construction > R302.4 Dwelling Unit Rated Penetrations > R302.4.2 Membrane Penetrations
714.3.2 Fire and Smoke Protection Features, Membrane Penetrations
space between the wall membrane and the box shall not exceed 1 / 8 inch (3.2 mm). Such boxes on opposite sides of the wall or partition shall ...
Building Code 2015 of Maryland > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.3 Fire-Resistance-Rated Walls > 714.3.2 Membrane Penetrations
714.4.2 Fire and Smoke Protection Features, Membrane Penetrations
annular space between the wall membrane and the box shall not exceed 1 / 8 inch (3.2 mm). Such boxes on opposite sides of the wall or partition shall ...
Building Code 2018 of Maryland > 7 Fire and Smoke Protection Features > 714 Penetrations > 714.4 Fire-Resistance-Rated Walls > 714.4.2 Membrane Penetrations
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING