• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

507.4.2 Noncanopy Size and Location

Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 507 Commercial Kitchen Hoods > 507.4 Hood Size and Location > 507.4.2 Noncanopy Size and Location
JUMP TO FULL CODE CHAPTER
Noncanopy-type hoods shall be located not greater than 3 feet (914 mm) above the cooking surface. The edge of the hood shall be set back not greater than 1 foot (305 mm) from the edge of the cooking surface.

Related Code Sections


507.4.2 Exhaust Systems, Noncanopy Size and Location
Noncanopy-type hoods shall be located not greater than 3 feet (914 mm) above the cooking surface. The edge of the hood shall be set back not greater ...
Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 507 Commercial Kitchen Hoods > 507.4 Hood Size and Location > 507.4.2 Noncanopy Size and Location
308.7.1 General Regulations, Location
For pipe sizes greater than 4 inches (102 mm), restraints shall be provided for drain pipes at all changes in direction and at all changes ...
Plumbing Code 2018 of Maryland > 3 General Regulations > 308 Piping Support > 308.7 Anchorage > 308.7.1 Location
708.1.5 Sanitary Drainage, Cleanout Size
that is one size larger than the P-trap size. Cleanouts located on stacks can be one size smaller than the stack size. The size of cleanouts for cast ...
Plumbing Code 2018 of Maryland > 7 Sanitary Drainage > 708 Cleanouts > 708.1 Cleanouts Required > 708.1.5 Cleanout Size
716.2.5.1 Fire and Smoke Protection Features, Size Limitations
located in fire walls and in fire barriers in accordance with Table 716.1(2) to the maximum size tested and in accordance with their listings ...
Building Code 2018 of Maryland > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.2 Fire Door Assemblies > 716.2.5 Glazing in Fire Door Assemblies > 716.2.5.1 Size Limitations
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING