• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5701.2 Nonapplicability

Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5701 General > 5701.2 Nonapplicability
JUMP TO FULL CODE CHAPTER
This chapter shall not apply to liquids as otherwise provided in other laws or regulations or chapters of this code, including:
  1. Specific provisions for flammable liquids in motor fuel-dispensing facilities, repair garages, airports and marinas in Chapter 23.
  2. Medicines, foodstuffs, cosmetics and commercial or institutional products containing not more than 50 percent by volume of water-miscible liquids and with the remainder of the solution not being flammable, provided that such materials are packaged in individual containers not exceeding 1.3 gallons (5 L).
  3. Quantities of alcoholic beverages in retail or wholesale sales or storage occupancies, provided that the liquids are packaged in individual containers not exceeding 1.3 gallons (5 L).
  4. Storage and use of fuel oil in tanks and containers connected to oil-burning equipment. Such storage and use shall be in accordance with Section 603. For abandonment of fuel oil tanks, this chapter applies.
  5. Refrigerant liquids and oils in refrigeration systems (see Section 605).
  6. Storage and display of aerosol products complying with Chapter 51.
  7. Storage and use of liquids that do not have a fire point when tested in accordance with ASTM D92.
  8. Liquids with a flash point greater than 95°F (35°C) in a water-miscible solution or dispersion with a water and inert (noncombustible) solids content of more than 80 percent by weight, which do not sustain combustion.
  9. Liquids without flash points that can be flammable under some conditions, such as certain halogenated hydrocarbons and mixtures containing halogenated hydrocarbons.
  10. The storage of distilled spirits and wines in wooden barrels and casks.
  11. Commercial cooking oil storage tank systems located within a building and designed and installed in accordance with Section 608 and NFPA 30.

Related Code Sections


2401.2 Flammable Finishes, Nonapplicability
This chapter shall not apply to spray finishing utilizing flammable or combustible liquids that do not sustain combustion, including: Liquids ...
Fire Code 2021 of Colorado > 24 Flammable Finishes > 2401 General > 2401.2 Nonapplicability
2401.2 Flammable Finishes, Nonapplicability
This chapter shall not apply to spray finishing utilizing flammable or combustible liquids that do not sustain combustion, including: Liquids ...
Fire Code 2018 of Colorado > 24 Flammable Finishes > 2401 General > 2401.2 Nonapplicability
4001.1.1 Storage of Distilled Spirits and Wines, Nonapplicability
Chapter 50 and Chapter 57 are not applicable to the storage of distilled spirits and wines in barrels and casks as identified in Section 5001.1 ...
Fire Code 2021 of Colorado > 40 Storage of Distilled Spirits and Wines > 4001 General > 4001.1 General > 4001.1.1 Nonapplicability
5701.2 Flammable and Combustible Liquids, Nonapplicability
This chapter shall not apply to liquids as otherwise provided in other laws or regulations or chapters of this code, including: Specific provisions ...
Fire Code 2021 of Colorado > 57 Flammable and Combustible Liquids > 5701 General > 5701.2 Nonapplicability
5701.2 Flammable and Combustible Liquids, Nonapplicability
This chapter shall not apply to liquids as otherwise provided in other laws or regulations or chapters of this code, including: Specific ...
Fire Code 2018 of Colorado > 57 Flammable and Combustible Liquids > 5701 General > 5701.2 Nonapplicability
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING