• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2106.1.1 Non-Participating Masonry Walls

NYC Building Code 2014 > 21 Masonry > 2106 Seismic Design > 2106.1 Seismic Design Requirements for Masonry > 2106.1.1 Non-Participating Masonry Walls
JUMP TO FULL CODE CHAPTER
Masonry walls that are not part of the lateral-force-resisting system shall be isolated from the structure so that the vertical and lateral forces are not imparted to these elements. Isolation joints and connectors between these elements and the structure shall be designed to accommodate the design story drift.

Related Code Sections


2106.1.1 Masonry, Non-Participating Masonry Walls
Masonry walls that are not part of the lateral-force-resisting system shall be isolated from the structure so that the vertical and lateral forces ...
NYC Building Code 2014 > 21 Masonry > 2106 Seismic Design > 2106.1 Seismic Design Requirements for Masonry > 2106.1.1 Non-Participating Masonry Walls
2106.1.1 Masonry, Non-Participating Masonry Walls
Masonry walls that are not part of the lateral-force-resisting system shall be isolated from the structure so that the vertical and lateral forces ...
NYC Building Code 2022 > 21 Masonry > 2106 Seismic Design > 2106.1 Seismic Design Requirements for Masonry > 2106.1.1 Non-Participating Masonry Walls
2109.5.6 Masonry, Foundation Walls
at the top of foundation walls prior to back-filling,   5. The length of foundation walls between perpendicular masonry walls or pilasters ...
NYC Building Code 2008 > 21 Masonry > 2109 Empirical Design of Masonry > 2109.5 Thickness of Masonry > 2109.5.6 Foundation Walls
2110.1 Masonry, Scope
This section covers the empirical requirements for non-load-bearing glass unit masonry elements in exterior or interior walls ...
NYC Building Code 2008 > 21 Masonry > 2110 Glass Unit Masonry > 2110.1 Scope
3309.8 Safeguards During Construction or Demolition, Adjoining Walls
When any construction or demolition operation exposes or breaches an adjoining wall, including load bearing and non load-bearing walls as well ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3309 Protection of Adjoining Property > 3309.8 Adjoining Walls
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING