2106.1.1 Non-Participating Masonry Walls
JUMP TO FULL CODE CHAPTER
Masonry walls that are not part of the lateral-force-resisting system shall be isolated from the structure so that the vertical and lateral forces are not imparted to these elements. Isolation joints and connectors between these elements and the structure shall be designed to accommodate the design story drift.
Related Code Sections
2106.1.1 Masonry, Non-Participating Masonry Walls
Masonry walls that are not part of the lateral-force-resisting system shall be isolated from the structure so that the vertical and lateral forces ...
NYC Building Code 2014 > 21 Masonry > 2106 Seismic Design > 2106.1 Seismic Design Requirements for Masonry > 2106.1.1 Non-Participating Masonry Walls
2106.1.1 Masonry, Non-Participating Masonry Walls
Masonry walls that are not part of the lateral-force-resisting system shall be isolated from the structure so that the vertical and lateral forces ...
NYC Building Code 2022 > 21 Masonry > 2106 Seismic Design > 2106.1 Seismic Design Requirements for Masonry > 2106.1.1 Non-Participating Masonry Walls
2109.5.6 Masonry, Foundation Walls
at the top of foundation walls prior to back-filling, 5. The length of foundation walls between perpendicular masonry walls or pilasters ...
NYC Building Code 2008 > 21 Masonry > 2109 Empirical Design of Masonry > 2109.5 Thickness of Masonry > 2109.5.6 Foundation Walls
2110.1 Masonry, Scope
This section covers the empirical requirements for non-load-bearing glass unit masonry elements in exterior or interior walls ...
3309.8 Safeguards During Construction or Demolition, Adjoining Walls
When any construction or demolition operation exposes or breaches an adjoining wall, including load bearing and non load-bearing walls as well ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3309 Protection of Adjoining Property > 3309.8 Adjoining Walls