• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1804.2.1 Nominally Unsatisfactory Bearing Material

NYC Building Code 2014 > 18 Soils and Foundations > 1804 Allowable Load-Bearing Values of Soils and Rock > 1804.2 Allowable Bearing Pressure > 1804.2.1 Nominally Unsatisfactory Bearing Material
JUMP TO FULL CODE CHAPTER
Organic silts, organic clays, peats, soft clays, loose granular soils, loose silts, and varved silts shall be considered nominally unsatisfactory bearing material. The allowable bearing pressure shall be determined independently of Table 1804.1 subject to the following:
  1. For varved silts, the soil bearing pressure produced by the proposed building shall not exceed 2 tons per square foot (192 kPa), except that for desiccated or over consolidated soils, higher bearing pressures are allowed subject to approval by the commissioner.
  2. For organic silts or clays, peats, soft clays, loose granular soils, or loose silts, the engineer responsible for the geotechnical investigation shall establish the allowable soil bearing pressure based upon the soil's specific engineering properties. This may require that the soils be preconsolidated, artificially treated or compacted.
  3. A report prepared, signed and sealed by the engineer is required to be filed with the department to substantiate the design soil pressures to be used on soil materials and shall contain, at a minimum:
    1. Sufficient laboratory test data on the compressible material to indicate the soil strength and the preconsolidation pressure, coefficient of consolidation, coefficient of compressibility, permeability, secondary compression characteristics, and Atterberg limits.
    2. Where the design contemplates improvement of the natural bearing capacity and/or reduction in settlements by virtue of preloading, cross sections showing the amount of fill and surcharge to be placed, design details showing the required time for surcharging, and computations showing the amount of settlement to be expected during surcharging and the estimated amount and rate of settlement expected to occur after the structure has been completed, including the influence of dead and live loads of the structure.
    3. A detailed analysis showing that the anticipated future settlement will not adversely affect the performance of the structure.
    4. Where strip drains, sand drains, or stone columns are to be used, computations showing the diameter, spacing, and anticipated method of installation of such drains.
    5. Records of settlement plate elevations and pore pressure readings, before, during, and after surcharging.

Related Code Sections


1804.2.1 Soils and Foundations, Nominally Unsatisfactory Bearing Material
Organic silts, organic clays, peats, soft clays, loose granular soils, loose silts, and varved silts shall be considered nominally unsatisfactory ...
NYC Building Code 2014 > 18 Soils and Foundations > 1804 Allowable Load-Bearing Values of Soils and Rock > 1804.2 Allowable Bearing Pressure > 1804.2.1 Nominally Unsatisfactory Bearing Material
§27-677 Foundations, Nominally Unsatisfactory Bearing Material
, or satisfactory bearing materials that contain lenses of, or are underlain by, these materials shall be considered as nominally unsatisfactory bearing ...
NYC 1968 Code (Vol I) > 11 Foundations > 4 Allowable Soil Bearing Pressures > §27-677 Nominally Unsatisfactory Bearing Material
1802.3 Soils and Foundations, Material Classification
be considered nominally unsatisfactory bearing material. SILTS AND CLAYEY SILTS. For soil types ML and MH in the absence of sufficient ...
NYC Building Code 2014 > 18 Soils and Foundations > 1802 Geotechnical Investigations and Material Classifications > 1802.3 Material Classification
§27-658 Foundations, Depth of Foundations
inspection of the rock surface directly underlying the bearing area shows it to be free of seams, cracks, or disintegrated materials that could serve ...
NYC 1968 Code (Vol I) > 11 Foundations > 1 General > §27-658 Depth of Foundations
1808.2.8.1.5.1 Soils and Foundations, Piles Installed by Use of Steam-Powered, Air-Powered, Diesel-Powered or Hydraulic Impact Hammers
unsatisfactory bearing material (Class 6 and uncontrolled fills, but not controlled fill) or to the bottom of the lowest stratum of soft ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.8 Allowable Pier or Pile Loads > 1808.2.8.1 Determination of Allowable Loads > 1808.2.8.1.5 Capacity as Indicated by Resistance to Penetration > 1808.2.8.1.5.1 Piles Installed by Use of Steam-Powered, Air-Powered, Diesel-Powered or Hydraulic Impact Hammers
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE