403.2.2.1 Night Clubs
JUMP TO FULL CODE CHAPTER
Audible announcements shall be made to the occupants no longer than 10 minutes prior to the start of the entertainment and at each intermission to notify the occupants of the location of the exits to be used in the event of a fire or other emergency.
Upon request of the fire code official, the owner or operator, or both, will be required to keep a running count of the occupant load to provide to the fire code official during performance hours of operation, entertainment hours of operation, or both.
Related Code Sections
403.2.2.1 Emergency Planning and Preparedness, Night Clubs
Night clubs shall comply with Sections 403.2.2.1.1 and 403.2.2.1.2 ...
2015 Virginia Statewide Fire Prevention Code > 4 Emergency Planning and Preparedness > 403 Emergency Preparedness Requirements > 403.2 Group A Occupancies > 403.2.2 Announcements > 403.2.2.1 Night Clubs
403.2.2.1 Emergency Planning and Preparedness, Night Clubs
Night clubs shall comply with Sections 403.2.2.1.1 and 403.2.2.1.2 ...
2012 Virginia Statewide Fire Prevention Code > 4 Emergency Planning and Preparedness > 403 Emergency Preparedness Requirements > 403.2 Group A Occupancies > 403.2.2 Announcements > 403.2.2.1 Night Clubs
403.2.2.1 Emergency Planning and Preparedness, Night Clubs
Night clubs shall comply with Sections 403.2.2.1.1 and 403.2.2.1.2 ...
2018 Virginia Statewide Fire Prevention Code > 4 Emergency Planning and Preparedness > 403 Emergency Preparedness Requirements > 403.2 Group A Occupancies > 403.2.2 Announcements > 403.2.2.1 Night Clubs
403.2.2.1.1 Emergency Planning and Preparedness, Audible Announcements
Audible announcements shall be made to the occupants no longer than 10 minutes prior to the start of the entertainment and at each intermission ...
2015 Virginia Statewide Fire Prevention Code > 4 Emergency Planning and Preparedness > 403 Emergency Preparedness Requirements > 403.2 Group A Occupancies > 403.2.2 Announcements > 403.2.2.1 Night Clubs > 403.2.2.1.1 Audible Announcements
403.2.2.1.2 Emergency Planning and Preparedness, Occupant Load Count
Upon request of the fire code official, the owner or operator, or both, will be required to keep a running count of the occupant load to provide ...
2015 Virginia Statewide Fire Prevention Code > 4 Emergency Planning and Preparedness > 403 Emergency Preparedness Requirements > 403.2 Group A Occupancies > 403.2.2 Announcements > 403.2.2.1 Night Clubs > 403.2.2.1.2 Occupant Load Count