• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

124-312 New Streets

NYC Zoning Resolution > XII Special Purpose Districts > 4 - Special Willets Point District (WP) > 124-30 Mandatory Improvements > 124-31 Standards for Streets and Blocks > 124-312 New Streets
JUMP TO FULL CODE CHAPTER
The provisions of this Section shall apply to all private streets constructed after November 13, 2008.
(a)        Primary retail street

One primary retail street shall be provided parallel to, or generally parallel to, 126th Street and comply with the following requirements:
(1)        The western boundary of such street shall be not less than 220 feet and not more than 320 feet from 126th Street.
(2)        Such street shall intersect two retail streets and two connector streets.
(3)        The width of such street shall be a minimum of 70 feet and a maximum of 80 feet, comprised of:
(i)        two 15 foot wide sidewalks, one adjacent to each curb;        
(ii)        two nine foot wide strips, one adjacent to each sidewalk which can be used as either parking lanes or pedestrian amenity areas that may include landscaping, seating and walkways;
(iii)        two travel lanes in the center of the street totaling 22 feet in width; and
(iv)        one optional eight to 10 foot wide landscaped median located on the centerline of the street between the two travel lanes provided that the street width shall not exceed 72 feet without such median.
(b)        Connector streets

Two connector streets shall be provided, as follows:
(1)        One connector street shall intersect 126th Street as shown on Map 5 in the Appendix to this Chapter.
(2)        One connector street shall intersect 126th Street opposite the south side of Citi Field Stadium within the 125 foot area shown on Map 5.
(3)        Both connector streets shall intersect with the primary retail street and with each other at a point east of the primary retail street.
(4)        The width of each connector street shall be at least 75 feet and no more than 86 feet, comprised of:
(i)        two 15 foot wide sidewalks, one adjacent to each curb;
(ii)        two nine foot wide strips, one adjacent to each sidewalk that can be used as either parking lanes or pedestrian amenity areas that may include landscaping, seating and walkways; and
(iii)        at least two travel lanes and not more than three travel lanes totaling at least 22 feet and not more than 33 feet in width, and one bike lane at least five feet wide.
(5)        Where a convention center fronts upon a connector street, the requirements set forth in this paragraph (b) shall be modified to eliminate the nine foot wide strip and, in lieu thereof, require a 12 foot wide drop off lane that, in the aggregate, shall not exceed 300 feet.
(c)        Retail streets

A minimum of two and maximum of three retail streets shall be provided, as follows:
(1)        One retail street shall intersect 126th Street opposite the entrance to Citi Field stadium, within the area shown on Map 5;
(2)        One retail street shall intersect 126th Street opposite the north side of Citi Field Stadium within the area shown on Map 5;
(3)        Two retail streets shall intersect with the primary retail street;
(4)        The width of each retail street shall be no more than 68 feet wide, comprised of:
(i)        two 13 foot wide sidewalks, one adjacent to each curb;
(ii)        two 10 foot wide strips, one adjacent to each sidewalk that can be used as pedestrian amenity areas that may include landscaping, seating and walkways; and
(iii)        two travel lanes totaling at least 22 feet in width.
(d)        Eastern perimeter street

One eastern perimeter street shall be provided as follows:
(1)        The eastern boundary of such street shall be within 20 feet of the eastern boundary of the Special Willets Point District, extending between Roosevelt Avenue and a connector street.
(2)        The width of such street shall be at least 62 feet and no more than 75 feet, comprised of:
(i)        a 13 foot wide sidewalk along its western boundary and a sidewalk at least five feet wide along its eastern boundary;
(ii)        two eight foot wide strips, one adjacent to each sidewalk that can be used as either a parking lane or as pedestrian amenity areas that may include landscaping, seating and walkways; and
(iii)        at least two and no more than three travel lanes totaling at least 20 feet and not more than 33 feet in width.
(e)        Residential streets

All streets, other than those listed in paragraphs (a) through (d) of this Section, that have one or more ground floor dwelling units fronting on the street shall be considered residential streets, except where such street is designated a service street pursuant to paragraph (f) of this Section. Residential streets shall be provided, as follows:
(1)        A residential street shall be a minimum of 62 feet wide and a maximum of 64 feet wide, comprised of:
(i)        two 13 foot wide sidewalks, one adjacent to each curb;
(ii)        two eight foot wide strips, one adjacent to each sidewalk that can be used as either a parking lane or as pedestrian amenity areas that may include landscaping, seating and walkways; and
(iii)        two travel lanes totaling between 20 and 22 feet in width.
(f)        Service streets

All newly constructed streets, other than those listed in paragraphs (a) through (e) of this Section, shall be improved as a service street. A minimum of 50 percent of the uses within stories on the ground floor or with a floor level within five feet of base flood elevation fronting a service street shall contain non-residential uses. Service streets shall be provided, as follows:
(1)        A service street may only be located as one of the streets bounding:
(i)        a block that bounds the intersection of 126th Street and Northern Boulevard; and
(ii)        a block that bounds the intersection of 126th Street and Roosevelt Avenue.
(2)        A service street shall be a minimum of 62 feet wide and a maximum of 64 feet wide, comprised of:
(i)        two 13 foot wide sidewalks, one adjacent to each curb;
(ii)        two eight foot wide strips, one adjacent to each sidewalk that can be used as either a parking lane or as pedestrian amenity areas that may include landscaping, seating and walkways; and
(iii)        two travel lanes totaling between 20 and 22 feet in width.

Related Code Sections


Reference Standard 2 Definitions [PDF] (page 2)
Reference Standard 2 Engineering & Safety Service 85 John Street New York, N.Y. 10038 ** AISI American Iron and Steel Institute Suite 1300 1101 ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 2 Definitions
Reference Standard 2 Definitions [PDF] (page 6)
of Commerce Washington, D. C. 20234 (Available from Superintendent of Documents) PSC New York State Public Service Commission NYC Office 400 Broome Street ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 2 Definitions
Reference Standard 2 Definitions [PDF] (page 5)
Reference Standard 2 Institute of Electrical and Electronics Engineers, Inc. 345 East 47th Street New York, N.Y. 10017 IES Illuminating Engineers ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 2 Definitions
Reference Standard 2 Definitions [PDF] (page 4)
Los Angeles, California 90032 (IBI) See AHA IC Industrial Code Rules New York State Department of Labor N.Y.C. Office One Main Street Gair Tower ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 2 Definitions
Reference Standard 2 Definitions [PDF] (page 3)
Street New York, New York 10165 CISPI Cast Iron Soil Pipe Institute Suite 419 5959 Shallowford Road Chattanooga, TN 37421 CFR Code of Federal ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 2 Definitions
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING