[BS] A304.2.5 New Hollow-Unit Masonry Foundations
JUMP TO FULL CODE CHAPTER
New hollow-unit masonry foundations shall be solidly grouted. The grout shall have minimum compressive strength of 2,000 pounds per square inch (13.79 MPa). Mortar shall be Type M or S.
Related Code Sections
A304.2.5 Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Wood-Frame Residential Buildings, New Hollow-Unit Masonry Foundations
New hollow-unit masonry foundations shall be solidly grouted. The grout shall have minimum compressive strength of 2,000 pounds per square inch ...
Existing Building Code 2015 of Idaho > A3 Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Wood-Frame Residential Buildings > A304 Strengthening Requirements > A304.2 Foundations > A304.2.5 New Hollow-Unit Masonry Foundations
R607.2.2.2 Wall Construction, Hollow Masonry
For hollow masonry units, head and bed joints shall be filled solidly with mortar for a distance in from the face of the unit not less than ...
2017 Idaho Residential Code > 6 Wall Construction > R607 Unit Masonry > R607.2 Placing Mortar and Masonry Units > R607.2.2 Masonry Unit Placement > R607.2.2.2 Hollow Masonry
R606.13.1.2 Wall Construction, Hollow Units
Where two or more hollow units are used to make up the thickness of a wall, the stretcher courses shall be bonded at vertical intervals not exceeding ...
Idaho Residential Code (2020 Edition) > 6 Wall Construction > R606 General Masonry Construction > R606.13 Multiple-Wythe Masonry > R606.13.1 Bonding With Masonry Headers > R606.13.1.2 Hollow Units
R608.1.1.2 Wall Construction, Hollow Units
Where two or more hollow units are used to make up the thickness of a wall, the stretcher courses shall be bonded at vertical intervals not exceeding ...
2017 Idaho Residential Code > 6 Wall Construction > R608 Multiple-Wythe Masonry > R608.1 General > R608.1.1 Bonding With Masonry Headers > R608.1.1.2 Hollow Units
R606.4.2 Wall Construction, Support at Foundation
or one-half the height of the unit. The hollow space behind the corbeled masonry shall be filled with mortar or grout ...
2017 Idaho Residential Code > 6 Wall Construction > R606 General Masonry Construction > R606.4 Support Conditions > R606.4.2 Support at Foundation