• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

419.0 Neonatal Intensive Care Units

California Mechanical Code 2019 > 4 Ventilation Air > 419.0 Neonatal Intensive Care Units
JUMP TO FULL CODE CHAPTER
[OSHPD 1]

419.1 Formula Preparation Area

Air shall be supplied over the formulation preparation area by group E, nonaspirating supply diffusers. Air shall be returned or exhausted by registers located not less than 3 inches (76 mm) nor more than 8 inches (203 mm) above the finished floor in the cleanup area.

419.2 Treatment Area/Room

Air shall be supplied over the treatment surface by group E, nonaspirating supply diffusers. Air shall be returned or exhausted by registers located not less than 3 inches (76 mm) nor more than 8 inches (203 mm) above the finished floor, adjacent to the treatment surface.

Related Code Sections


419.0 Ventilation Air, Neonatal Intensive Care Units
[OSHPD 1] Air shall be supplied over ...
California Mechanical Code 2019 > 4 Ventilation Air > 419.0 Neonatal Intensive Care Units
1224.29.2.12 Interior Environment, Housekeeping Room
Shall be directly accessible from the unit and be dedicated for the exclusive use of the neonatal intensive care unit ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.12 Housekeeping Room
1224.29.2.12 Interior Environment, Housekeeping Room
Shall be directly accessible from the unit and be dedicated for the exclusive use of the neonatal intensive care unit ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.12 Housekeeping Room
1224.29.2 Interior Environment, Newborn Intensive Care Units (NICU)
for the exclusive use of the neonatal intensive care unit ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU)
1224.29 Interior Environment, Intensive Care Units
units, coronary-care service spaces, pediatric intensive-care service spaces unless otherwise noted. Each unit shall comply with the following provisions ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING