• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 110.5 Natural Gas Central Furnaces, Cooking Equipment, and Pool and Spa Heaters: Pilot Lights Prohibited

California Energy Code 2016 > 2 All Occupancies—Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components > 110.5 Natural Gas Central Furnaces, Cooking Equipment, and Pool and Spa Heaters: Pilot Lights Prohibited
JUMP TO FULL CODE CHAPTER
Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light:
(a) Fan-type central furnaces.
(b) Household cooking appliances.
Exception to Section 110.5(b): Household cooking appliances without an electrical supply voltage connection and in which each pilot consumes less than 150 Btu/hr.
(c) Pool heaters.
(d) Spa heaters.

Related Code Sections


A5.207.4 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], Natural Gas Central Furnaces, Cooking Equipment and Pool and Spa Heaters: Pilot Lights Prohibited
Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light: Fan-type central ...
California Green Building Standards Code 2016 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.207 [OSHPD 1, 2 & 4] HVAC Design, Equipment and Installation > A5.207.4 Natural Gas Central Furnaces, Cooking Equipment and Pool and Spa Heaters: Pilot Lights Prohibited
A5.207.4 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], Natural Gas Central Furnaces, Cooking Equipment and Pool and Spa Heaters: Pilot Lights Prohibited
Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light: Fan-type central ...
California Green Building Standards Code 2019 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.207 [OSHPD 1, 2 & 4] HVAC Design, Equipment and Installation > A5.207.4 Natural Gas Central Furnaces, Cooking Equipment and Pool and Spa Heaters: Pilot Lights Prohibited
Section 110.5 All Occupancies—Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components, Natural Gas Central Furnaces, Cooking Equipment, and Pool and Spa Heaters: Pilot Lights Prohibited
Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light: (a) Fan-type central ...
California Energy Code 2016 > 2 All Occupancies—Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components > 110.5 Natural Gas Central Furnaces, Cooking Equipment, and Pool and Spa Heaters: Pilot Lights Prohibited
Section 110.5 All Occupancies — Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components, Natural Gas Central Furnaces, Cooking Equipment, Pool and Spa Heaters,and Fireplaces: Pilot Lights Prohibited
Any natural gas system or equipment listed below may be installed only if it does not have a continuously burning pilot light: Fan-type central ...
California Energy Code 2019 > 2 All Occupancies — Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components > 110.5 Natural Gas Central Furnaces, Cooking Equipment, Pool and Spa Heaters,and Fireplaces: Pilot Lights Prohibited
Section A5.505 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], [OSHPD 1, 2 & 4] Indoor Moisture Control
Efficiency. □ □    A5.207.3.3 Installation. □ □ A5.207.4 Natural gas central furnaces, cooking equipment and pool and spa heaters ...
California Green Building Standards Code 2016 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.505 [OSHPD 1, 2 & 4] Indoor Moisture Control
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING