// CODE SNIPPET
§3616-05 National Fire Protection Association ("NFPA") 13R Amendment Relating to Exemption From Fire Department Connection Requirements in One- And Two-Family Residential Buildings. [Repealed]
JUMP TO FULL CODE CHAPTER
(Repealed eff. 10/8/2015)
*Subchapter Q added City Record May 11, 2009 § 1, eff. June 10, 2009.
**Note that an asterisk (**) found withing the foregoing rule, following the number or letter designating a paragraph, indicates that explanatory material on the paragraph can be found in Annex A of NFPA 13.
Related Code Sections
903.3.1.2 Fire Protection Systems, NFPA 13R Sprinkler Systems
in accordance with NFPA 13R. The number of stories of Group R occupancies constructed in accordance with Sections 510.2 and 510.4 shall be measured from ...
NYC Building Code 2022 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.2 NFPA 13R Sprinkler Systems
903.3.1.1 Fire Protection Systems, NFPA 13 Sprinkler Systems
Department, automatic sprinklers shall not be required in rooms or areas protected with an approved automatic fire detection system in accordance with Section ...
NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.1 NFPA 13 Sprinkler Systems
Section Q104 Modified National Standards for Automatic Sprinkler, Standpipe, Fire Pump, Fire Alarm, and Smoke Control Systems, Installation of Sprinkler Systems in Residential Occupancies
with the referenced standard NFPA-13-2016 as modified for New York City. A Fire Department connection is not required in one-and two-family dwellings ...
NYC Building Code 2022 > Q Modified National Standards for Automatic Sprinkler, Standpipe, Fire Pump, Fire Alarm, and Smoke Control Systems > Q104 Installation of Sprinkler Systems in Residential Occupancies
2.2 Referenced Publications, NFPA Publications
National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 11, Standard for Low-, Medium-, and High-Expansion Foam ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 2 Referenced Publications > 2.2 NFPA Publications
903.3.1.2 Fire Protection Systems, NFPA 13R Sprinkler Systems
in accordance with NFPA 13R as modified in Appendix Q ...
NYC Building Code 2008 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.2 NFPA 13R Sprinkler Systems