• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R602.12.6 Narrow Panels

Residential Code 2018 of Kansas > 6 Wall Construction > R602 Wood Wall Framing > R602.12 Simplified Wall Bracing > R602.12.6 Narrow Panels
JUMP TO FULL CODE CHAPTER
The bracing methods referenced in Section R602.10 and specified in Sections R602.12.6.1 through R602.12.6.3 shall be permitted where using simplified wall bracing.

R602.12.6.1 Method CS-G

Braced wall panels constructed as Method CS-G in accordance with Tables R602.10.4 and R602.10.5 shall be permitted for one-story garages where all framed portions of all exterior walls are sheathed with wood structural panels. Each CS-G panel shall be equivalent to 0.5 of a bracing unit. Segments of wall that include a Method CS-G panel shall meet the requirements of Section R602.10.4.2.

R602.12.6.2 Method CS-PF

Braced wall panels constructed as Method CS-PF in accordance with Section R602.10.6.4 shall be permitted where all framed portions of all exterior walls are sheathed with wood structural panels. Each CS-PF panel shall equal 0.75 bracing units. Not more than four CS-PF panels shall be permitted on all segments of walls parallel to each side of the circumscribed rectangle. Segments of wall that include a Method CS-PF panel shall meet the requirements of Section R602.10.4.2.

R602.12.6.3 Methods ABW, PFH and PFG

Braced wall panels constructed as Method ABW, PFH and PFG shall be permitted where bracing units are constructed using wood structural panels applied either continuously or intermittently. Each ABW and PFH panel shall equal one bracing unit and each PFG panel shall be equal to 0.75 bracing unit.

Related Code Sections


R602.12.6 Wall Construction, Narrow Panels
wall bracing. Braced wall panels constructed ...
Residential Code 2018 of Kansas > 6 Wall Construction > R602 Wood Wall Framing > R602.12 Simplified Wall Bracing > R602.12.6 Narrow Panels
2.11.11.5 Electric Elevators, Panels
Panels shall conform to 2.11.11.5.1 through 2.11.11.5.8 ...
Safety Code for Elevators and Escalators 2016 of Kansas > 2 Electric Elevators > 2.11 Protection of Hoistway Openings > 2.11.11 Entrances, Horizontal Slide Type > 2.11.11.5 Panels
2.11.13.3 Electric Elevators, Panels
Panels shall conform to 2.11.13.3.1 through 2.11.13.3.7 ...
Safety Code for Elevators and Escalators 2016 of Kansas > 2 Electric Elevators > 2.11 Protection of Hoistway Openings > 2.11.13 Entrances, Swinging Type > 2.11.13.3 Panels
408.50 Equipment for General Use, Panels
The panels of switchboards and switchgear shall be made of moisture-resistant, noncombustible material ...
National Electrical Code 2017 of Kansas > 4 Equipment for General Use > 408 Switchboards, Switchgear, and Panelboards > 408.50 Panels
7.2.2.2.2 Means of Egress, Curved Stairs
) at a point 12 in. (305 mm) from the narrower end of the tread and the smallest radius is not less than twice the stair width ...
Life Safety Code 2018 of Kansas > 7 Means of Egress > 7.2 Means of Egress Components > 7.2.2 Stairs > 7.2.2.2 Dimensional Criteria > 7.2.2.2.2 Curved Stairs
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING