23-841 Narrow Outer Courts
JUMP TO FULL CODE CHAPTER
R1 R2 R3 R4 R5
(a) In the districts indicated, if an outer court is less than 30 feet wide, the width of such outer court shall be at least one and one-third the depth of such outer court.
However, in R3, R4 or R5 Districts, for single- and two-family residences, three stories or less in height, the width of such outer court shall be at least equal to the depth of such outer court.
However, in R3, R4 or R5 Districts, for single- and two-family residences, three stories or less in height, the width of such outer court shall be at least equal to the depth of such outer court.
R6 R7 R8 R9 R10
(b) In the districts indicated, if an outer court is less than 30 feet wide, the width of such outer court shall be at least equal to the depth of such outer court. However, the depth of an outer court may exceed its width in a small outer court, provided that:
(1) no legally required windows shall face onto such small outer court or any outer court recess thereof;
(2) such small outer court is located above the level of the first story ;
(3) the area of such small outer court shall not be less than 200 square feet and no dimension shall be less than 10 feet; and
(4) where the perimeter walls of such small outer court exceed a height of 75 feet, as measured from the lowest level of such outer court, at least 50 percent of such perimeter walls above a height of 75 feet shall setback 10 feet from the court opening. However, the depth of such required setback may be reduced one foot for every foot the minimum dimension of such court exceeds a width of 10 feet.
Related Code Sections
1206.3 Interior Environment, Courts
:
Outer courts that open to a street
Courts that exceed the minimum dimension set forth in the Zoning Resolution of the City of New York by at least 50 ...
1206.3 Interior Environment, Courts
walls enclosing courts of multiple dwellings shall be of light colored materials or shall be painted a light color. Exceptions: Outer courts ...
1206.3 Interior Environment, Courts
All walls enclosing courts of multiple dwellings shall be of light colored materials or shall be painted a light color.
Exceptions:
Outer ...
Section 1206 Interior Environment, Yards and Courts
:
Outer courts that open to a street.
Courts that exceed the minimum dimension set forth in the New York City Zoning Resolution by at least 50 percent ...
Article 13 Special Occupancy Structures [PDF] (page 13)
of courts upon inadequate streets. Where a street faces upon a public street narrower than the court which would be required for emergency purposes ...